1.05787
HPTLC plates, Cellulose
pkg of 25 plates, plate L × W 10 cm × 10 cm, glass support
Sinonimo/i:
Cellulose TLC Plates
Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali
About This Item
Prodotti consigliati
Materiali
cellulose matrix
glass support
Livello qualitativo
Caratteristiche
binder Organic Polymer
fluorescent indicator: no
Confezionamento
pkg of 25 plates
tecniche
thin layer chromatography (TLC): suitable
Spessore strato
60-110 μm
Lungh. × largh. lastra
10 cm × 10 cm
Temperatura di conservazione
2-30°C
Descrizione generale
25 Glass plates 10 x 10 cm
Cellulose plates are used to analyze polar substances. An organic sorbent, cellulose is perfect for separating hydrophilic substances by partition chromatography. Typical applications include the analysis of amino acids, carbohydrates, and phosphates as well as nucleic acid and nucleic acid derivatives. We offer cellulose plates in two grades: TLC for conventional and HPTLC for demanding, high-performance separations.
Applicazioni
- Fast assessment of planar chromatographic layers quality using pulse thermovision method: Focuses on the quality control of cellulose HPTLC plates, ensuring the reliability of chromatographic processes in various research and industrial applications (Suszyński et al., 2014).
- High-performance thin-layer chromatographic-densitometric determination of secoisolariciresinol diglucoside in flaxseed: Utilizes cellulose HPTLC plates for precise quantification of bioactive compounds in natural products, serving the needs of the nutraceutical and pharmaceutical industries (Coran et al., 2004).
Linkage
Replaces: 5787-5; 5787
Risultati analitici
Layer thickness: 60 - 110 µm
Deviation of layer thickness per plate: ≤ 30 µm
Aminoacid test
hRf-values
- L-serine, amino acid test:
20 - 30
- L-threonine, amino acid test: 30 - 40
- L-alanine, amino acid test: 35 - 45
- L-methionine, amino acid test: 55 - 65
- L-phenylalanine, amino acid test: 60 - 70
- L-leucine, amino acid test: 70 - 80
Typical value determined on a plate
Eluent: 1-Butanol/ acetone/ acetic acid/ water (35/35/7/23 v/v/v/v) twice developed
Deviation of layer thickness per plate: ≤ 30 µm
Aminoacid test
hRf-values
- L-serine, amino acid test:
20 - 30
- L-threonine, amino acid test: 30 - 40
- L-alanine, amino acid test: 35 - 45
- L-methionine, amino acid test: 55 - 65
- L-phenylalanine, amino acid test: 60 - 70
- L-leucine, amino acid test: 70 - 80
Typical value determined on a plate
Eluent: 1-Butanol/ acetone/ acetic acid/ water (35/35/7/23 v/v/v/v) twice developed
Certificati d'analisi (COA)
Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.