Passa al contenuto
Merck
Tutte le immagini(3)

Documenti fondamentali

444545

Sigma-Aldrich

Cobalt(II) 2-ethylhexanoate solution

65 wt. % in mineral spirits

Sinonimo/i:

2-Ethylhexanoic acid cobalt(2+) salt, Bis(2-ethylhexanoate)cobalt, Cobalt bis(2-ethylhexanoate), Cobalt octoate, Cobaltous octoate

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali

Scegli un formato

100 ML
42,90 €
500 ML
153,00 €

42,90 €


Per informazioni sulla disponibilità, contatta il Servizio Clienti.

Richiedi un ordine bulk

Scegli un formato

Cambia visualizzazione
100 ML
42,90 €
500 ML
153,00 €

About This Item

Formula condensata:
[CH3(CH2)3CH(C2H5)CO2]2Co
Numero CAS:
Peso molecolare:
345.34
Numero MDL:
Codice UNSPSC:
12352103
ID PubChem:
NACRES:
NA.23

42,90 €


Per informazioni sulla disponibilità, contatta il Servizio Clienti.

Richiedi un ordine bulk

Stato

liquid

Livello qualitativo

Composizione

Co, 11.0-13.0% EDTA titration

Impiego in reazioni chimiche

core: cobalt

Concentrazione

65 wt. % in mineral spirits

Densità

1.002 g/mL at 25 °C

Stringa SMILE

CCCCC(CC)C(=O)O[Co]OC(=O)C(CC)CCCC

InChI

1S/2C8H16O2.Co/c2*1-3-5-6-7(4-2)8(9)10;/h2*7H,3-6H2,1-2H3,(H,9,10);/q;;+2/p-2
QAEKNCDIHIGLFI-UHFFFAOYSA-L

Applicazioni

Polymerization accelerator

Avvertenze

Danger

Classi di pericolo

Aquatic Acute 1 - Aquatic Chronic 3 - Asp. Tox. 1 - Eye Irrit. 2 - Flam. Liq. 3 - Repr. 1B - Resp. Sens. 1 - Skin Sens. 1 - STOT SE 3

Organi bersaglio

Central nervous system

Rischi supp

Codice della classe di stoccaggio

3 - Flammable liquids

Classe di pericolosità dell'acqua (WGK)

WGK 3

Punto d’infiammabilità (°F)

104.0 °F - closed cup

Punto d’infiammabilità (°C)

40 °C - closed cup

Dispositivi di protezione individuale

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


Elenchi normativi

Forniamo informazioni su eventuali restrizioni prevalentemente per i prodotti chimici. Per altre tipologie di prodotto siamo in grado di fornire soltanto informazioni limitate. Nessuna segnalazione significa che nessuno dei componenti è citato in un elenco. È dovere dell’utilizzatore assicurarsi che il prodotto venga impiegato in maniera sicura e a norme di legge.

EU REACH Annex XVII (Restriction List)

CAS No.

Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

Non trovi la versione di tuo interesse?

Se hai bisogno di una versione specifica, puoi cercare il certificato tramite il numero di lotto.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

I clienti hanno visto anche

Slide 1 of 2

1 of 2

Eliška Matušková et al.
Materials (Basel, Switzerland), 13(3) (2020-02-07)
This paper reports a strong drying activity of manganese(III) acetylacetonate. It is documented on several solvent-borne and high-solid alkyd binders. Solubility problems, which often appear upon application of new primary driers, were overcome by use of dimethyl sulfoxide. Interestingly, intense
Offset printer's occupational allergic contact dermatitis caused by cobalt-2-ethylhexoate.
L Kanerva et al.
Contact dermatitis, 34(1), 67-68 (1996-01-01)
Occupational cobalt-allergic contact dermatitis resulting from polyester resin.
Jennifer L Cahill et al.
Contact dermatitis, 63(5), 292-294 (2010-10-16)
Namrata S Anavekar et al.
The Australasian journal of dermatology, 47(2), 143-144 (2006-04-28)
A 46-year-old woman, who worked as a laminator of spa baths, presented with hand dermatitis, which was suspected to be related to her occupation. Patch testing revealed strong reactions to both cobalt chloride and a polyester resin that the patient
Jan Honzíček et al.
Materials (Basel, Switzerland), 14(5) (2021-04-04)
This study describes the catalytic performance of an iron(III) complex bearing a phthalocyaninato-like ligand in two solvent-borne and two high-solid alkyd binders. Standardized mechanical tests revealed strong activity, which appeared in particular cases at concentrations about one order of magnitude

Domande

1–2 di 2 domande  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 risposta
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Utile?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 risposta
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Utile?

Recensioni

Nessuna valutazione

Filtri attivi

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.