HMYOMAG-56K
MILLIPLEX® Human Myokine Magnetic Bead Panel
The Human Myokine Panel, using the Luminex xMAP technology, enables the simultaneous analysis of 15 myokine protein biomarkers in human serum, plasma and cell/tissue culture samples.
About This Item
Javasolt termékek
Minőségi szint
faj reaktivitás
human
gyártó/kereskedő neve
Milliplex®
assay range
accuracy: 100%
(Apelin)
accuracy: 92%
(IL-15)
accuracy: 96%
(FSTL-1)
accuracy: 97%
(LIF)
accuracy: 98%
(Oncostatin M (OSM))
sensitivity: 0.9 pg/mL
(MinDC+2SD; IL-6)
sensitivity: 14 pg/mL
(MinDC+2SD; FGF-21)
sensitivity: 259 pg/mL
(MinDC+2SD; Myostatin/GDF8)
sensitivity: 281 pg/mL
(MinDC+2SD; Irisin)
sensitivity: 4 pg/mL
(MinDC+2SD; LIF)
sensitivity: 40 pg/mL
(MinDC+2SD; Fractalkine/CX3CL1)
sensitivity: 5 pg/mL
(MinDC+2SD; IL-15)
sensitivity: 59 pg/mL
(MinDC+2SD; Osteocrin/Musclin)
sensitivity: 6 pg/mL
(MinDC+2SD; Oncostatin M (OSM))
sensitivity: 64 pg/mL
(MinDC+2SD; Apelin)
sensitivity: 7.5 ng/mL
(MinDC+2SD; Osteonectin (SPARC))
sensitivity: 737 pg/mL
(MinDC+2SD; Follistatin-like Protein 1 (FSTL1))
sensitivity: 815 pg/mL
(MinDC+2SD; Erythropoietin (EPO))
sensitivity: 9 pg/mL
(MinDC+2SD; BDNF)
sensitivity: 9.8 pg/mL
(MinDC+2SD; FABP3)
standard curve range: 0.6-2,400 pg/mL
(IL-6)
standard curve range: 10-40,000 pg/mL
(LIF)
standard curve range: 122-500,000 pg/mL
(Apelin)
standard curve range: 2-10,000 pg/mL
(BDNF)
standard curve range: 2-10,000 pg/mL
(IL-15)
standard curve range: 2-6,000 pg/mL
(Oncostatin M (OSM))
standard curve range: 24-100,000 pg/mL
(FABP3)
standard curve range: 244-1,000,000 pg/mL
(Erythropoietin (EPO))
standard curve range: 244-1,000,000 pg/mL
(Irisin)
standard curve range: 488-2,000,000 pg/mL
(Follistatin-like Protein 1 (FSTL1))
standard curve range: 488-2,000,000 pg/mL
(Myostatin/GDF8)
standard curve range: 49-200,000 pg/mL
(Fractalkine/CX3CL1)
standard curve range: 49-200,000 pg/mL
(Osteocrin/Musclin)
standard curve range: 5-20,000 pg/mL
(FGF-21)
standard curve range: 7-30,000 ng/mL
(Osteonectin (SPARC))
inter-assay cv: <15%
intra-assay cv: <10%
(Apelin)
inter-assay cv: <15%
intra-assay cv: <10%
(BDNF)
inter-assay cv: <15%
intra-assay cv: <10%
(Erythropoietin (EPO))
inter-assay cv: <15%
intra-assay cv: <10%
(FABP3)
inter-assay cv: <15%
intra-assay cv: <10%
(FGF-21)
inter-assay cv: <15%
intra-assay cv: <10%
(Follistatin-like Protein 1 (FSTL1))
inter-assay cv: <15%
intra-assay cv: <10%
(Fractalkine/CX3CL1)
inter-assay cv: <15%
intra-assay cv: <10%
(IL-15)
inter-assay cv: <15%
intra-assay cv: <10%
(IL-6)
inter-assay cv: <15%
intra-assay cv: <10%
(Irisin)
inter-assay cv: <15%
intra-assay cv: <10%
(LIF)
inter-assay cv: <15%
intra-assay cv: <10%
(Myostatin/GDF8)
inter-assay cv: <15%
intra-assay cv: <10%
(Oncostatin M (OSM))
inter-assay cv: <15%
intra-assay cv: <10%
(Osteocrin/Musclin)
inter-assay cv: <20%
intra-assay cv: <10%
(Osteonectin (SPARC))
technika/technikák
multiplexing: suitable
észlelési módszer
fluorometric (Luminex xMAP)
kiszállítva
wet ice
Általános leírás
MILLIPLEX® Human Myokine Panel is a15-plex kit to be used for the simultaneous quantification of any or all of the following analytes in human serum,plasma and cell/tissue supernatant samples: Fractalkine/CX3CL1, BDNF, Oncostatin M (OSM), Osteonectin (SPARC), LIF, FGF-21, Erythropoietin (EPO), IL-15, IL-6, Apelin, Myostatin/GDF8, Irisin, Osteocrin/Musclin, FABP3 and Follistatin-Like Protein (FSTL 1). This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.
The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.
Panel Type: Metabolism
Alkalmazás
- Analytes: Apelin (APLN), Brain-derived Neurotrophic Factor (BDNF), Erythropoeitin (EPO), Fatty Acid-Binding Protein 3 (FABP3), Fibroblast Growth Factor 21 (FGF21), Fractalkine (CX3CL1), Follistatin-Like 1 Protein (FSTL-1), IL-6, IL-15, Irisin, Leukemia Inhibitory Factor (LIF), Myostatin (MSTN/GDF8), Oncostatin M (OSM), Osteocrin (OSTN/Musclin), Osteonectin (SPARC)
- Recommended Sample Type: Human serum, plasma, and cell/tissue culture supernatants or lysates
- NOTE: Substantial amounts of BDNF are stored in circulating platelets and subsequently released upon platelet activation. Therefore, platelet-poor plasma is critical to ensure accurate measurement of circulating levels of BDNF.
- Recommended Sample Dilution: 25 μL per well of 1:2 diluted serum or plasma. Cell/tissue culture samples may be run neat or appropriately diluted in control media.
- Assay Run Time: Overnight (16-18 hours) at 2-8°C or 2 hours at room temperature (20-25°C)
- Research Category: Bone
- Research Subcategory: Metabolism
Tulajdonságok és előnyök
Egyéb megjegyzések
Jogi információk
Figyelmeztetés
Danger
Figyelmeztető mondatok
Óvintézkedésre vonatkozó mondatok
Veszélyességi osztályok
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Irrit. 2 - Skin Sens. 1 - STOT RE 2
Célzott szervek
Respiratory Tract
Tárolási osztály kódja
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
Analitikai tanúsítványok (COA)
Analitikai tanúsítványok (COA) keresése a termék sarzs-/tételszámának megadásával. A sarzs- és tételszámok a termék címkéjén találhatók, a „Lot” vagy „Batch” szavak után.
Már rendelkezik ezzel a termékkel?
Az Ön által nemrégiben megvásárolt termékekre vonatkozó dokumentumokat a Dokumentumtárban találja.
Related Content
Myokine analysis with multiplex immunoassays, such as the MILLIPLEX® Human Myokine Panel, allow researchers to simultaneously measure multiple muscle-secreted factors, providing more insights into related diseases.
Simplify protein biomarker discovery with the MILLIPLEX® PLEXpedition 115-Plex Multiplex Screening Panel. Effortlessly screen cytokines and other markers with Luminex® technology.
Multiplex immunoassays, such as MILLIPLEX® multiplex metabolic assays, are critical in metabolic syndrome research because they provide a full picture of the different conditions related to it, like diabetes and obesity, as well as save time and sample volume.
Tudóscsoportunk valamennyi kutatási területen rendelkezik tapasztalattal, beleértve az élettudományt, az anyagtudományt, a kémiai szintézist, a kromatográfiát, az analitikát és még sok más területet.
Lépjen kapcsolatba a szaktanácsadással