Ugrás a tartalomra
Merck
Összes fotó(1)

Fontos dokumentumok

03-0196-00

Millipore

SMC® Human Total α-synuclein High Sensitivity Immunoassay Kit

Uses 100 µL per well of 1:200 diluted serum or plasma samples, or 1:10 diluted cerebrospinal fluid (CSF) samples.

Szinonimák:

Human α-synuclein, α-synuclein, Human total-α-synuclein, a-synuclein, total-a-synuclein

Bejelentkezésa Szervezeti és Szerződéses árazás megtekintéséhez


About This Item

UNSPSC kód:
12161503
NACRES:
NA.84

faj reaktivitás

canine, rat, feline, mouse

gyártó/kereskedő neve

SMC®

assay range

sensitivity: 1.95  pg/mL
(LLOQ of Total α-synuclein)

inter-assay cv: 14%
intra-assay cv: 9%
(five normal plasma samples run in triplicate by 3 different operators on 3 different days)

technika/technikák

single molecule counting: suitable

Általános leírás

The SMC® Human Total-α-Synuclein High Sensitivity Immunoassay Kit contains all reagents required to perform the assay. This assay takes advantage of a standard immunoassay workflow configured in a standard plate format. Assay protocols are similar to existing sandwich ELISA methods with two key differences:
1) Elution buffer disrupts the sandwich, separating the labeled detection antibody for quantification.
2) The Erenna and SMCxPRO® immunoassay systems detect analytes using Single Molecule Counting (SMC®) technology.

Egyediség

Species Reactivity Note

Specificity to the following species samples were tested with the following results:
Monkey – 100%
Cat – 100%
Rat – 100%
Mouse – 100%
Beagle – 100%

Cross Reactivity

Cross-reactivity to the following analytes were tested with the following results:
Tau – 0%UCHL1 – 0%
β-synuclein – 0%
γ-synuclein – 0%

Accuracy

CSF Recovery: 5 CSF samples spiked with average recovery of 96% and a range of 90-102%
Serum Recovery: 4 serum samples spiked with average recovery of 96% and a range of 93-98%
Plasma Recovery: 4 plasma samples spiked with average recovery of 96% and a range of 93-97%

Alkalmazás

Uses 100 µL per well of 1:200 diluted serum or plasma samples, or 1:10 diluted cerebrospinal fluid (CSF) samples.

Kiszerelés

96 well assay

Komponensek

  • Assay Buffer
  • Total α-synuclein Coated Beads
  • Standard Diluent
  • Total α-synuclein Detection Antibody
  • Total α-synuclein Standard
  • 10X Wash Buffer
  • Buffer D
  • Elution Buffer B

Egyéb megjegyzések

  • This new streamline kit has the following features:
  • Improved options for sample prep and incubation
  • Lyophilization protein standard for uniform shipping and storage condition
  • Increased reagent volumes to accommodate automation
  • Able to achieve assay specifications on both SMCxPRO® and Erenna.

Jogi információk

SMC is a registered trademark of Singulex
SMCxPRO is a registered trademark of Merck KGaA, Darmstadt, Germany

Jogi nyilatkozat

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Piktogramok

Skull and crossbonesHealth hazard

Figyelmeztetés

Danger

Figyelmeztető mondatok

Veszélyességi osztályok

Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 3 - Eye Irrit. 2 - Repr. 1B

Tárolási osztály kódja

6.1D - Non-combustible acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects

Lobbanási pont (F)

Not applicable

Lobbanási pont (C)

Not applicable


Analitikai tanúsítványok (COA)

Analitikai tanúsítványok (COA) keresése a termék sarzs-/tételszámának megadásával. A sarzs- és tételszámok a termék címkéjén találhatók, a „Lot” vagy „Batch” szavak után.

Már rendelkezik ezzel a termékkel?

Az Ön által nemrégiben megvásárolt termékekre vonatkozó dokumentumokat a Dokumentumtárban találja.

Dokumentumtár megtekintése

Related Content

Discover how to expand neuroscience biomarker research with high sensitivity immunoassays, such as Single Molecule Counting (SMC®) assays. These assays give researchers the tools they need to detect low-abundant blood-based biomarkers and expand biomarker options in neuroscience research.

Explore high-sensitivity SMC® neurology immunoassays that precisely measure low levels of neurology protein analytes, such as NF-L or Tau proteins.

Find immunoassays to explore neuroimmunology and neuroinflammation cytokines and neurodegenerative disease biomarkers.

Tudóscsoportunk valamennyi kutatási területen rendelkezik tapasztalattal, beleértve az élettudományt, az anyagtudományt, a kémiai szintézist, a kromatográfiát, az analitikát és még sok más területet.

Lépjen kapcsolatba a szaktanácsadással