跳转至内容
Merck

D-907

Supelco

地西泮标准液 溶液

1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

登录查看公司和协议定价


About This Item

经验公式(希尔记法):
C16H13ClN2O
CAS号:
分子量:
284.74
EC號碼:
MDL號碼:
分類程式碼代碼:
41116107
PubChem物質ID:
NACRES:
NA.24

等級

certified reference material

形狀

liquid

特點

Snap-N-Spike®/Snap-N-Shoot®

包裝

ampule of 1 mL

製造商/商標名

Cerilliant®

drug control

Narcotic Licence Schedule B (Switzerland); psicótropo (Spain); Decreto Lei 15/93: Tabela IV (Portugal)

濃度

1.0 mg/mL in methanol

技術

gas chromatography (GC): suitable
liquid chromatography (LC): suitable

應用

clinical testing

格式

single component solution

儲存溫度

-10 to -25°C

SMILES 字串

CN1C(=O)CN=C(c2ccccc2)c3cc(Cl)ccc13

InChI

1S/C16H13ClN2O/c1-19-14-8-7-12(17)9-13(14)16(18-10-15(19)20)11-5-3-2-4-6-11/h2-9H,10H2,1H3

InChI 密鑰

AAOVKJBEBIDNHE-UHFFFAOYSA-N

正在寻找类似产品? 访问 产品对比指南

一般說明

该认证加标溶液® 适用于通过 HPLC、GC/MS 或 LC-MS/MS 法测试地西泮,从而用于法医分析、临床毒理学、尿液药物测试和大麻效力或杂质分析测试等应用。

地西泮是一种抗焦虑的苯二氮卓类药物,通常用于治疗焦虑症、肌肉痉挛和急性癫痫发作等。

應用

该认证标准物质(CRM)还可作如下用途:
  • 基于富勒烯功能化碳纳米管和离子液体修饰电极(C60-CNTs/IL)以电化学方式测定血清、尿液和片剂中的地西泮
  • 使用铋修饰的预处理铅笔石墨电极(BiPPGE)以差分伏安法分析地西泮片剂和人尿样品
  • 通过直接电子电离-液相色谱-串联质谱(EI-LC-MS/MS)法同时定量测定酒精饮料样品中的安定和氟硝西泮
  • 使用分散纳米材料-超声辅助-微萃取(DNUM)从尿液和血浆样品中提取地西泮和氯二氮环氧化物,并通过高效液相色谱-紫外(HPLC-UV)检测定量
  • 通过固相萃取后跟 LC-MS/MS 法测定对人口服液中安定及其代谢物进行多残留分析

特點和優勢

  • 完全符合 ISO/IEC 17025 和 ISO 17034 认证
  • 附综合分析证书(CoA),包括稳定性、均匀性、浓度准确性、不确定性和可追溯性数据
  • 通过实时稳定性研究严格测试,以确保准确性和保质期
  • 使用合格的精密天平进行重量准备,以确保最小不确定性
  • 氩气环境下火焰密封,装入安瓿以便长期保存
  • 提供方便的 DEA 豁免格式,以提高实验室效率

法律資訊

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
CERTIFIED SPIKING SOLUTION is a registered trademark of Cerilliant Corporation
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany

相關產品

产品编号
说明
价格

訊號詞

Danger

危險分類

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

標靶器官

Eyes,Central nervous system

儲存類別代碼

3 - Flammable liquids

水污染物質分類(WGK)

WGK 2

閃點(°F)

49.5 °F - closed cup

閃點(°C)

9.7 °C - closed cup


分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Electrochemical determination of diazepam in real samples based on fullerene-functionalized carbon nanotubes/ionic liquid nanocomposite
Rahimi-Nasrabadi M, et al.
Sensors and Actuators B, Chemical, 240, 125-131 (2017)
Voltammetric determination of diazepam using a bismuth modified pencil graphite electrode
Dehghanzade M and Alipour E
Analytical Methods : Advancing Methods and Applications, 8, 1995-2004 (2016)
A Amiri Pebdani et al.
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 1008, 146-155 (2015-12-15)
Benzodiazepines (BDs) are used widely in clinical practice, due to their multiple pharmacological functions. In this study a dispersive nanomaterial-ultrasound assisted- microextraction (DNUM) method followed by high performance liquid chromatography (HPLC) was used for the preconcentration and determination of chlordiazepoxide
Berend Malchow et al.
Journal of neural transmission (Vienna, Austria : 1996), 122(7), 1019-1033 (2014-10-14)
Hippocampus volumes have been shown to be decreased in patients with major depression, but volume measurements are inconsistent in patients with bipolar disorder. Both disorders are associated with deficits in hippocampus-mediated cognitive functions. However, the underlying pathophysiology is widely unknown.
Haim Bassan et al.
Epilepsia, 54(6), 1092-1098 (2013-04-05)
Prolonged febrile seizures (PFS) lasting ≥15 min have been associated with increased risk for epilepsy in later life. Initial treatment, mostly prehospital, aims to prevent its evolution to febrile status epilepticus (FSE) and reduce adverse outcome. Paucity of information is

商品

The application note describes a comparative analysis of plasma protein binding results for free/bound drugs using two different sample extraction steps, with and without agitation.

Comparative analysis of Supel™ BioSPME 96-Pin device with a rapid equilibrium dialysis technique for accuracy of measured values, sample cleanliness, and workflow time in drug protein binding.

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门