Accéder au contenu
Merck
Toutes les photos(1)

Documents

77515

Sigma-Aldrich

Methylene Blue solution

for microscopy

Synonyme(s) :

Loeffler’s Methylene Blue

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Formule empirique (notation de Hill):
C16H18ClN3S
Numéro CAS:
Poids moléculaire :
319.85
Numéro Beilstein :
3641570
Numéro MDL:
Code UNSPSC :
12171500
ID de substance PubChem :
Nomenclature NACRES :
NA.47

Qualité

for microscopy

Forme

solution

Durée de conservation

limited shelf life, expiry date on the label

Technique(s)

microbe id | staining: suitable

Spectre d'activité de l'antibiotique

Gram-negative bacteria
Gram-positive bacteria

Adéquation

Corynebacterium spp.
bacteria
mycobacteria
spore forming microorganisms

Chaîne SMILES 

[Cl-].CN(C)c1ccc2N=C3C=C\C(C=C3Sc2c1)=[N+](/C)C

InChI

1S/C16H18N3S.ClH/c1-18(2)11-5-7-13-15(9-11)20-16-10-12(19(3)4)6-8-14(16)17-13;/h5-10H,1-4H3;1H/q+1;/p-1

Clé InChI

CXKWCBBOMKCUKX-UHFFFAOYSA-M

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Catégories apparentées

Application

Loefflers Methylene Blue stain is used for the identification of diphteria bacilli, since it differentiates the deeply staining metachromatic granules from the pale blue-staining cytoplasm.

Composants

Composition:
methylene blue 0.3 g
ethanol 30 ml
water 100 ml

Remplacé(e)(s) par

Pictogrammes

Flame

Mention d'avertissement

Warning

Mentions de danger

Classification des risques

Flam. Liq. 3

Code de la classe de stockage

3 - Flammable liquids

Classe de danger pour l'eau (WGK)

WGK 2

Point d'éclair (°F)

113.0 °F

Point d'éclair (°C)

45 °C

Équipement de protection individuelle

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Vous ne trouvez pas la bonne version ?

Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Xiaojuan Bai et al.
Langmuir : the ACS journal of surfaces and colloids, 29(9), 3097-3105 (2013-02-20)
ZnO1-x/graphene hybrid photocatalyst was prepared via a facile in-situ reduction of graphene oxide and ZnO1-x surface defect oxide. The hybrid photocatlayst showed enhanced photocatalytic activity for the photodegradation of methylene blue. The photocorrosion of ZnO1-x was successfully inhibited by graphene
Jonel Steffen et al.
The British journal of ophthalmology, 98(1), 13-15 (2013-10-26)
To evaluate the diagnostic accuracy of methylene blue used as a non-invasive in vivo stain to detect ocular surface squamous neoplasia (OSSN). A test validation study was performed according to Standards for the reporting of diagnostic accuracy studies (STARD) guidelines
Nicolaas Lucius Gerlach et al.
Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons, 72(4), 666-671 (2014-02-01)
To establish the accuracy of cone-beam computed tomographic (CBCT) views in determining the position and diameter of the mandibular canal. Two freshly frozen cadaver heads, 1 dentate and 1 edentate, were used to acquire CBCT scans. Measurements on cross-sectional CBCT
Q R J G Tummers et al.
European journal of surgical oncology : the journal of the European Society of Surgical Oncology and the British Association of Surgical Oncology, 40(7), 850-858 (2014-05-28)
Despite recent developments in preoperative breast cancer imaging, intraoperative localization of tumor tissue can be challenging, resulting in tumor-positive resection margins during breast conserving surgery. Based on certain physicochemical similarities between Technetium((99m)Tc)-sestamibi (MIBI), an SPECT radiodiagnostic with a sensitivity of
Bram Vivijs et al.
Applied and environmental microbiology, 80(19), 6054-6061 (2014-07-27)
Some members of the family Enterobacteriaceae ferment sugars via the mixed-acid fermentation pathway. This yields large amounts of acids, causing strong and sometimes even lethal acidification of the environment. Other family members employ the 2,3-butanediol fermentation pathway, which generates comparatively

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique