54278-U
BPE-DNPH solid phase extraction (SPE) Cartridge
bed B 270 mg (DNPH-coated silica), bed A 130 mg (2-BPE coated silica), volume 3 mL, pkg of 10 ea
Synonym(e):
BPE-DNPH cartridge tube
About This Item
Empfohlene Produkte
product name
BPE-DNPH Cartridge, bed B 270 mg (DNPH-coated silica), bed A 130 mg (2-BPE coated silica), volume 3 mL, pkg of 10 ea
Agentur
ASTM® D5197 (BPE layer acts as a built-in ozone scrubber; not affected by moisture or high humidity conditions.)
EPA IP-6A,TO-11A (BPE layer acts as a built-in ozone scrubber; not affected by moisture or high humidity conditions.)
NIOSH 2016 (BPE layer suitable from scrubbing ozone from sample)
Beschreibung
Dual-layer air sampling device.
Zusammensetzung
bed A, 130 mg (2-BPE coated silica)
bed B, 270 mg (DNPH-coated silica)
Verpackung
pkg of 10 ea
Methode(n)
active air sampling: suitable
Volumen
3 mL
Anwendung(en)
air monitoring
industrial hygiene
Lagertemp.
2-8°C
Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich
Allgemeine Beschreibung
It is a well-known problem when sampling airborne carbonyls using DNPH-coated silica gel devices that ozone interferes with their analysis. To remove this ozone interference, traditional ozone scrubbing devices containing 1.5 g of Potassium Iodide (KI) are used in front of the DNPH device to trap the ozone, which causes negative ozone interference. In high humidity environments and rainy conditions, potassium iodide cartridges (or other multiple bed devices containing both potassium iodide and DNPH) result in sample loss, due to moisture condensation and collection inside the device.
Benefits:
- Integrated ozone scrubber
- No extra connections
- No leaking cartridges
- High Purity adsorbents for better accuracy in trace analysis
- Low Background
- Individual packaging in zip seal bag to maximize sample integrity
- Suitable for NIOSH 2016, EPA TO-11A, EPA IP-6A and ASTM D5197
Anwendung
Rechtliche Hinweise
Signalwort
Warning
H-Sätze
Gefahreneinstufungen
Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3
Zielorgane
Respiratory system
Lagerklassenschlüssel
11 - Combustible Solids
WGK
WGK 3
Flammpunkt (°F)
Not applicable
Flammpunkt (°C)
Not applicable
Choose from one of the most recent versions:
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Kunden haben sich ebenfalls angesehen
Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..
Setzen Sie sich mit dem technischen Dienst in Verbindung.