Direkt zum Inhalt
Merck

T6399

Sigma-Aldrich

Trichloressigsäure

ACS reagent, ≥99.0%

Synonym(e):

TCA

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise

Größe auswählen

5 G
47,40 €
100 G
66,30 €
4 X 100 G
155,00 €
250 G
158,00 €
500 G
179,00 €
1 KG
215,00 €

47,40 €


Voraussichtliches Versanddatum23. April 2025


Bulk-Bestellung anfordern

Größe auswählen

Ansicht ändern
5 G
47,40 €
100 G
66,30 €
4 X 100 G
155,00 €
250 G
158,00 €
500 G
179,00 €
1 KG
215,00 €

About This Item

Lineare Formel:
Cl3CCOOH
CAS-Nummer:
Molekulargewicht:
163.39
Beilstein:
970119
EG-Nummer:
MDL-Nummer:
UNSPSC-Code:
12352100
PubChem Substanz-ID:
NACRES:
NA.21

47,40 €


Voraussichtliches Versanddatum23. April 2025


Bulk-Bestellung anfordern

Qualität

ACS reagent

Qualitätsniveau

Dampfdichte

<1 (vs air)

Dampfdruck

1 mmHg ( 51 °C)

Assay

≥99.0%

Verunreinigungen

Substances darkened by sulfuric acid, passes test
≤0.01% insoluble matter

Glührückstand

≤0.03%

Brechungsindex

n20/D 1.62 (lit.)

bp

196 °C (lit.)

mp (Schmelzpunkt)

54-58 °C (lit.)

Löslichkeit

H2O: 1 g/10 mL

Dichte

1.62 g/mL at 25 °C (lit.)

Anionenspuren

chloride (Cl-): ≤0.002%
nitrate (NO3-): ≤0.002%
phosphate (PO43-): ≤5 ppm
sulfate (SO42-): ≤0.02%

Kationenspuren

Fe: ≤0.001%
heavy metals (as Pb): ≤0.002%

Funktionelle Gruppe

carboxylic acid
chloro

Lagertemp.

2-8°C

SMILES String

OC(=O)C(Cl)(Cl)Cl

InChI

1S/C2HCl3O2/c3-2(4,5)1(6)7/h(H,6,7)

InChIKey

YNJBWRMUSHSURL-UHFFFAOYSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Verwandte Kategorien

Anwendung

  • Trichloressigsäure wird zur Ausfällung von zirkulierendem sLRP (Soluble Low Density Lipoprotein Receptor-related Protein-1) isoliert vom Plasma verwendet.[1]
  • Es kommt auch bei der Extraktion von Ascorbinsäure aus Pflanzenproben zum Einsatz. Zudem wird es zur Herstellung von Ascorbat-Standards für den Ascorbat-Assay verwendet.[2]
  • Es wird auch zur Ausfällung von mittels IMAC (Immobilized Metal Ion Affinity Chromatography) isolierten Phosphoproteinen verwendet.[3]
Traditionell zur Fällung von Proteinen verwendet. Zur Bestimmung der Proteinkonzentration durch quantitative Fällung. Zum Entkalken und als Fixationsmittel in der Mikroskopie verwendet.

Ähnliches Produkt

Produkt-Nr.
Beschreibung
Preisangaben

Piktogramme

CorrosionEnvironment

Signalwort

Danger

H-Sätze

Gefahreneinstufungen

Aquatic Acute 1 - Aquatic Chronic 1 - Eye Dam. 1 - Skin Corr. 1A

Lagerklassenschlüssel

8B - Non-combustible corrosive hazardous materials

WGK

WGK 2

Flammpunkt (°F)

Not applicable

Flammpunkt (°C)

Not applicable

Persönliche Schutzausrüstung

Eyeshields, Faceshields, Gloves, type P3 (EN 143) respirator cartridges


Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Die passende Version wird nicht angezeigt?

Wenn Sie eine bestimmte Version benötigen, können Sie anhand der Lot- oder Chargennummer nach einem spezifischen Zertifikat suchen.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Casein Kinase 2 (CK2)-mediated Phosphorylation of Hsp90? as a Novel Mechanism of Rifampin-induced MDR1 Expression.
Kim SW et al.
The Journal of Biological Chemistry, 290, 17029-17029 (2015)
Measurement of reduced, oxidized and total ascorbate content in plants.
Gillespie KM and Ainsworth EA
Nature Protocols, 2, 871-871 (2007)
Impaired lipoprotein receptor-mediated peripheral binding of plasma amyloid-? is an early biomarker for mild cognitive impairment preceding Alzheimer's disease.
Sagare AP et al.
Journal of Alzheimer'S Disease, 24, 25-25 (2011)
Seokjo Kang et al.
Journal of Alzheimer's disease : JAD, 70(3), 667-680 (2019-07-01)
Increased levels of total tau (t-tau) and hyperphosphorylated tau (p-tau) proteins in the cerebrospinal fluid of Alzheimer's disease (AD) patients are well documented and strongly correlate with AD pathology. Recent studies have further shown that human tau can be released
Philip D Campbell et al.
The Journal of neuroscience : the official journal of the Society for Neuroscience, 34(44), 14717-14732 (2014-10-31)
Mutations in Kinesin proteins (Kifs) are linked to various neurological diseases, but the specific and redundant functions of the vertebrate Kifs are incompletely understood. For example, Kif5A, but not other Kinesin-1 heavy-chain family members, is implicated in Charcot-Marie-Tooth disease (CMT)

Fragen

1-4 von 4 Fragen  
  1. The answer stated 7 month ago says that "A 100% (w/v) solution of TCA can be made by the addition of 227 ml of water to 500 g of TCA." The powder purity being 99%, why wouldn't it be 100g of TCA for 100 mL of water for a 100% w/v solution?

    1 Antwort
    1. The formula "A 100% (w/v) solution of TCA can be made by the addition of 227 mL of water to 500 g of TCA" is sourced from Molecular Cloning: A Laboratory Manual, 3rd ed., Sambrook, J. F., et al., Cold Spring Harbor Laboratory Press (Cold Spring Harbor, NY: 2001), p. A1.29.
      Solutions should be prepared accurately at any given temperature by weighing into a volumetric flask, dissolving, and then bringing to the specified volume. The Molecular Cloning application may not have required an accurate solution. Volumes prepared using graduated cylinders are less accurate than those prepared using a To Contain class A volumetric flask, even if densities have been established. Unless specifically following the Molecular Cloning paper, it is best to prepare the solution using the established and correct method.

      Hilfreich?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 Antwort
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Hilfreich?

  3. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 Antwort
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Hilfreich?

  4. What are the recommended solubility and storage conditions for the trichloroacetic acid (TCA) product with CAS number 76-03-9?

    1 Antwort
    1. A 100% (w/v) solution of TCA can be made by the addition of 227 ml of water to 500 g of TCA. The resulting clear solution will have a density of approximately 1.45 g/ml. Do not use plastic dishes and containers. Solution storage temperature 2-8 °C

      Hilfreich?

Bewertungen

Kein Beurteilungswert

Aktive Filter

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.