581343-U
Ascentis® C18 (5 µm) HPLC Columns
L × I.D. 25 cm × 10 mm, HPLC Column
Synonyma:
Ascentis RP18 HPLC Column
About This Item
Doporučené produkty
product name
Ascentis® C18 HPLC Column, 5 μm particle size, L × I.D. 25 cm × 10 mm
material
stainless steel column
agency
suitable for USP L1 (Similar to Phenomenex Luna C18)
product line
Ascentis®
feature
endcapped
manufacturer/tradename
Ascentis®
packaging
1 ea of
extent of labeling
25% Carbon loading
parameter
≤70 °C temp. range
400 bar pressure (5801 psi)
technique(s)
HPLC: suitable
L × I.D.
25 cm × 10 mm
surface area
450 m2/g
surface coverage
3.7 μmol/m2
impurities
<5 ppm metals
matrix
fully porous particle
silica gel high purity, spherical
matrix active group
C18 (octadecyl) phase
particle size
5 μm
pore size
100 Å
operating pH range
2-8
application(s)
food and beverages
separation technique
reversed phase
Hledáte podobné produkty? Navštivte Průvodce porovnáváním produktů
General description
Ascentis C18 is an extremely stable and reliable first choice HPLC column that gives symmetric peak shape and excellent retention even for difficult compounds.
Application
- A dilute-and-shoot liquid chromatography-tandem mass spectrometry method for urinary 18-hydroxycortisol quantification and its application in establishing reference intervals: This paper details the application of Ascentis® C18 columns in a clinical setting to measure cortisol levels in urine. The method provides a fast, accurate, and reliable way to assess patient hormonal profiles, critical for diagnosing endocrine disorders (Zhao et al., 2022).
- A Comparative Study on Analysis of Ginsenosides in American Ginseng Root Residue by HPLC-DAD-ESI-MS and UPLC-HRMS-MS/MS: Utilizing Ascentis® C18, this study compares different analytical methods for quantifying ginsenosides. It showcases the column′s adaptability and precision in natural product research, essential for ensuring the quality and efficacy of herbal medicines (Hsu et al., 2022).
- Validation of a Rapid and Easy-to-Apply Method to Simultaneously Quantify Co-Loaded Dexamethasone and Melatonin PLGA Microspheres by HPLC-UV: Highlighting the Ascentis® C18′s effectiveness in pharmaceutical formulations, this research demonstrates its capacity to analyze complex drug delivery systems, contributing to the development of more effective therapeutic solutions (Brugnera et al., 2022).
- Simultaneous determination of ivermectin, clorsulon and their related substances in an injectable finished product by a stability-indicating RP-HPLC method: This publication illustrates the application of the Ascentis® C18 in veterinary medicine, providing crucial insights into drug stability and composition which are vital for regulatory compliance and animal safety (Padivitage et al., 2022).
Features and Benefits
- Excellent retention
- Symmetric peak shape
- High reproducibility
- Complete LC-MS compatibility
Legal Information
related product
Storage Class
11 - Combustible Solids
wgk_germany
WGK 3
flash_point_f
Not applicable
flash_point_c
Not applicable
Vyberte jednu z posledních verzí:
Již tento produkt vlastníte?
Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.
Zákazníci si také prohlíželi
Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..
Obraťte se na technický servis.