Přejít k obsahu
Merck
Všechny fotografie(1)

Hlavní dokumenty

11813-U

Supelco

Coated GC Packing

phase 3% SP®-1500, matrix 80/120 Carbopack B support, bottle of 15 g

Přihlásitk zobrazení cen stanovených pro organizaci a smluvních cen


About This Item

EC Number:
UNSPSC Code:
23151817
NACRES:
SB.54

packaging

bottle of 15 g

parameter

60-230 temp. range

technique(s)

gas chromatography (GC): suitable

matrix

80/120 Carbopack B support

matrix active group

3% SP®-1500 phase

column type

packed GC

compatibility

for analyte group industrial solvents

Hledáte podobné produkty? Navštivte Průvodce porovnáváním produktů

General description

Ready-to-use coated packing for those wanting to pack their own columns.
The choice of coating material is based on the stationary phase of the GC. SP 1500 on carbopack B packing is basically graphitized carbon that has a nominal surface area of 100 m2/g modified with small amounts of petrolatum and polyethylene glycol compound.

Legal Information

SP is a registered trademark of Sigma-Aldrich Co. LLC

Storage Class

11 - Combustible Solids

wgk_germany

nwg

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

Eyeshields, Gloves, type P3 (EN 143) respirator cartridges


Vyberte jednu z posledních verzí:

Osvědčení o analýze (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Dokumenty section.

Potřebujete-li pomoc, obraťte se na Zákaznická podpora

Již tento produkt vlastníte?

Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.

Navštívit knihovnu dokumentů

Multiple purge technique for determining organic pollutants in groundwater.
R P Kozloski et al.
Bulletin of environmental contamination and toxicology, 29(1), 1-6 (1982-07-01)
Modern Practice of Gas Chromatography.
Grob RL and Barry EF.
Science, 23-24 (2007)
Analytical Measurements in Aquatic Environments.
Namiesnik J and Szefer P..
Science, 73-73 (2009)
S Møller et al.
Applied and environmental microbiology, 62(12), 4632-4640 (1996-12-01)
As a representative member of the toluene-degrading population in a biofilter for waste gas treatment, Pseudomonas putida was investigated with a 16S rRNA targeting probe. The three-dimensional distribution of P. putida was visualized in the biofilm matrix by scanning confocal

Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..

Obraťte se na technický servis.