GE28-9031-34
Protein G High Performance Spintrap™
Cytiva 28-9031-34, pack of 16 columns
Synonyma:
Protein G Column
About This Item
Doporučené produkty
ligand
recombinant protein G lacking albumin-binding region
feature
wetted part: no
packaging
pack of 16 columns
manufacturer/tradename
Cytiva 28-9031-34
storage condition
(20% Ehtanol)
(20% Ethanol)
matrix
highly cross-linked 6% agarose
avg. part. size
34 μm
cleaning
2-9
working range
3-9
capacity
>1 mg binding capacity (lgG/column)(The binding capacity has been determined with human polyclonal IgG.)
>1 mg binding capacity(human IgG/column)
storage temp.
2-8°C
General description
Application
There is also a protocol for efficient, small-scale purification of monoclonal and polyclonal antibodies from serum and cell culture supernatants in less than 20 min. No pretreatment of the sample is required.
Features and Benefits
- For simple, small-scale purification of antibodies or enrichment of specific Proteins in prepacked spin columns that are ready to use.
- Classic and cross-link protocols provide flexibility.
- Elution conditions formatted for both electrophoresis and LC-MS analysis workflows.
- Fast binding kinetics and high capacity provides high yield.
- Prepacked with Protein G Sepharose™ High Performance for coupling of antibodies of IgG subclasses.
- Easy scale-up with HiTrap® Protein G HP prepacked columns.
Storage and Stability
Analysis Note
Legal Information
signalword
Warning
hcodes
Storage Class
3 - Flammable liquids
Osvědčení o analýze (COA)
Vyhledejte osvědčení Osvědčení o analýze (COA) zadáním čísla šarže/dávky těchto produktů. Čísla šarže a dávky lze nalézt na štítku produktu za slovy „Lot“ nebo „Batch“.
Již tento produkt vlastníte?
Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.
Zákazníci si také prohlíželi
Sortimentní položky
This page describes immunoprecipitation (immunoaffinity or pull-down techniques).
Desalting at laboratory scale is a well-proven, simple, and fast method that will rapidly remove low molecular weight contaminants at the same time as transferring the sample into the desired buffer in a single step.
Protokoly
This page shows how to separate IgG antibodies by affinity chromatography using Protein G HP SpinTrap™/Ab SpinTrap™ from Cytiva.
Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..
Obraťte se na technický servis.