Přejít k obsahu
Merck
Všechny fotografie(2)

Hlavní dokumenty

472360

Sigma-Aldrich

Poly(oxy-1,4-phenylenesulfonyl-1,4-phenylene)

melt index 6 g/10 min (380°C/2.16 kg)

Synonyma:

Poly(1,4-phenylene ether-sulfone)

Přihlásitk zobrazení cen stanovených pro organizaci a smluvních cen


About This Item

Lineární vzorec:
(C12H8O3S)n
Číslo CAS:
MDL number:
UNSPSC Code:
12162002
PubChem Substance ID:
NACRES:
NA.23

form

granular

melt index

6 g/10 min (380°C/2.16 kg)

ISO 1628

50 mL/g, in phenol/1,2-dichlorobenzene(lit.)

transition temp

Tg (DSC) 221 °C (onset)

solubility

aniline, dimethylacetamide and pyridine: soluble

density

1.37 g/mL at 25 °C (lit.)

SMILES string

Oc1ccc(cc1)S(=O)(=O)c2ccc(O)cc2

InChI key

VPWNQTHUCYMVMZ-UHFFFAOYSA-N

Hledáte podobné produkty? Navštivte Průvodce porovnáváním produktů

Application

Used in electrical connectors, printed circuit boards, sterilizable equipment and appliance covers.

pictograms

Exclamation mark

signalword

Warning

hcodes

Hazard Classifications

Acute Tox. 4 Oral

Storage Class

11 - Combustible Solids

wgk_germany

WGK 1

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

dust mask type N95 (US), Eyeshields, Gloves


Vyberte jednu z posledních verzí:

Osvědčení o analýze (COA)

Lot/Batch Number

Nevidíte správnou verzi?

Potřebujete-li konkrétní verzi, můžete vyhledat daný certifikát podle čísla dávky nebo čísla šarže.

Již tento produkt vlastníte?

Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.

Navštívit knihovnu dokumentů

Daniel Schneditz et al.
Clinical hemorheology and microcirculation, 58(3), 455-469 (2013-11-21)
It was the aim to examine the fluid flow in blood and dialysate compartments of highly permeable hollow fiber dialyzers where internal filtration contributes to solute removal but where excessive filtration bears a risk of cell activation and damage. Flow
Mario Bonomini et al.
Therapeutics and clinical risk management, 14, 1-9 (2018-01-04)
The success and the quality of hemodialysis therapy are mainly related to both clearance and biocompatibility properties of the artificial membrane packed in the hemodialyzer. Performance of a membrane is strongly influenced by its interaction with the plasma protein repertoire
Shogo Takamuku et al.
ChemSusChem, 6(2), 308-319 (2013-01-12)
The morphologies and proton-transport efficiencies of segmented copoly(arylene ether sulfone) ionomers that contain tetrasulfonated sequences are compared with the corresponding copolymers with disulfonated sequences. Tetrasulfonated 4,4'-bis[(4-chlorophenyl)sulfonyl]-1,1'-biphenyl (sBCPSBP) is synthesized by metalation and sulfination. This new monomer is then used in
Min Tang et al.
Journal of colloid and interface science, 386(1), 428-440 (2012-08-23)
Sulfonated polyethersulfone (SPES) and poly (acrylonitrile-co-acrylic acid-co-vinyl pyrrolidone) (P(AN-AA-VP)), which provided sulfonic acid (-SO(3)H) and carboxylic acid groups (-COOH), respectively, were used to modify polyethersulfone (PES) membrane with a heparin-like surface by blending method. The SPES was prepared by sulfonation
Dongsheng Wang et al.
Langmuir : the ACS journal of surfaces and colloids, 28(37), 13284-13293 (2012-08-17)
In the present study, photoresponsive surface molecularly imprinted poly(ether sulfone) microfibers are prepared via nitration reaction, the wet-spinning technique, surface nitro reduction reaction, and surface diazotation reaction for the selectively photoregulated uptake and release of 4-hydrobenzoic acid. The prepared molecularly

Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..

Obraťte se na technický servis.