wire, diam. 2.0 mm, 99.9% trace metals basis

Synonyma:

Platinum black, Platinum element, Platinum gray

Přihlásitk zobrazení cen stanovených pro organizaci a smluvních cen


About This Item

Empirický vzorec (Hillův zápis):
Pt
Číslo CAS:
Molekulová hmotnost:
195.08
EC Number:
MDL number:
UNSPSC Code:
12141734
PubChem Substance ID:
NACRES:
NA.23

assay

99.9% trace metals basis

form

wire

resistivity

10.6 μΩ-cm, 20°C

diam.

2.0 mm

bp

3827 °C (lit.)

mp

1772 °C (lit.)

density

21.45 g/cm3 (lit.)

SMILES string

[Pt]

InChI

1S/Pt

InChI key

BASFCYQUMIYNBI-UHFFFAOYSA-N

General description

Platinum (Pt) wire is a metal wire that is a biocompatible material that can be used in electrodes and implants. The efficiency of the platinum electrode can be improved by forming a platinum black surface.

Quantity

1.4 g = 2 cm; 7 g = 10 cm

Storage Class

13 - Non Combustible Solids

wgk_germany

nwg

flash_point_f

Not applicable

flash_point_c

Not applicable


Osvědčení o analýze (COA)

Vyhledejte osvědčení Osvědčení o analýze (COA) zadáním čísla šarže/dávky těchto produktů. Čísla šarže a dávky lze nalézt na štítku produktu za slovy „Lot“ nebo „Batch“.

Již tento produkt vlastníte?

Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.

Navštívit knihovnu dokumentů

Zákazníci si také prohlíželi

Slide 1 of 8

1 of 8

Platinum gauze, 100 mesh, 99.9% trace metals basis

Sigma-Aldrich

298093

Platinum

Platinum wire, diam. 0.127 mm, 99.99% trace metals basis

Sigma-Aldrich

267163

Platinum

Platinum wire reel, 0.2m, diameter 0.25mm, hard, 99.95%

GF35898924

Platinum

Platinum wire, diam. 0.25 mm, 99.99% trace metals basis

Sigma-Aldrich

267171

Platinum

Platinum wire, diam. 0.25 mm, thermocouple grade

Sigma-Aldrich

373265

Platinum

Platinum gauze, 52 mesh, 99.9% trace metals basis

Sigma-Aldrich

298107

Platinum

Platinum evaporation slug, diam. × L 0.6 cm × 1.2 cm, 99.99% trace metals basis

Sigma-Aldrich

373214

Platinum

Platinum shot, ≤3 mm, ≥99.9% trace metals basis

Sigma-Aldrich

327484

Platinum

Electrodes
Bioimpedance and Bioelectricity Basics, 179-254 (2015)
Synthesis of novel ruthenium sensitizers and their application in dye-sensitized solar cells
Nazeeruddin MK, et al.
Coordination Chemistry Reviews, 249(13-14), 1460-1467 (2005)
Electrode array design and fabrication for implantable systems
Implantable Sensor Systems for Medical Applications, 249(13-14), 150-182 (2013)
Wei Sun et al.
Materials science & engineering. C, Materials for biological applications, 33(4), 1907-1913 (2013-03-19)
In this paper a platinum (Pt) nanoparticle decorated graphene (GR) nanosheet was synthesized and used for the investigation on direct electrochemistry of myoglobin (Mb). By integrating GR-Pt nanocomposite with Mb on the surface of carbon ionic liquid electrode (CILE), a
Shai Rozen et al.
Plastic and reconstructive surgery, 131(6), 1253-1265 (2013-05-30)
Left untreated, paralytic lagophthalmos may result in corneal dryness, ulcerations, and subsequent blindness. The most common nondynamic surgical solution is upper eyelid weight placement in a superficial, pretarsal pocket, carrying the risk of visibility, extrusion, and entropion. The authors present

Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..

Obraťte se na technický servis.