Přejít k obsahu
Merck
Všechny fotografie(2)

Key Documents

181161

Sigma-Aldrich

Nylon 12

pellets

Synonyma:

Polylauryllactam

Přihlásitk zobrazení cen stanovených pro organizaci a smluvních cen


About This Item

Lineární vzorec:
(C12H23NO)n
Číslo CAS:
MDL number:
UNSPSC Code:
12162002
PubChem Substance ID:
NACRES:
NA.23

form

pellets

particle size

3-4 mm

transition temp

Tm 178 °C
Tg 37 °C

density

1.01 g/mL at 25 °C (lit.)

SMILES string

O=C1CCCCCCCCCCCN1

Application

  • Replicating and Redesigning Ankle-Foot Orthoses with 3D Printing for Children with Charcot-Marie-Tooth Disease.: This study highlights the use of 3D printing with Nylon 12 for creating custom ankle-foot orthoses, enhancing comfort and functionality for pediatric patients. (Wojciechowski et al., 2022).

Storage Class

11 - Combustible Solids

wgk_germany

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable


Osvědčení o analýze (COA)

Vyhledejte osvědčení Osvědčení o analýze (COA) zadáním čísla šarže/dávky těchto produktů. Čísla šarže a dávky lze nalézt na štítku produktu za slovy „Lot“ nebo „Batch“.

Již tento produkt vlastníte?

Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.

Navštívit knihovnu dokumentů

Zákazníci si také prohlíželi

Slide 1 of 4

1 of 4

Polyamide 6 United States Pharmacopeia (USP) Reference Standard

USP

1372344

Polyamide 6

Polyamide for column chromatography, 6

Supelco

02395

Polyamide

Kosuke Tomita et al.
Biotechnology letters, 25(20), 1743-1746 (2003-11-25)
A thermophilic bacterium, identified as a neighboring species to Geobacillus thermocatenulatus, having a growth optimum at 55 degrees C and, capable of degrading nylon 12, was isolated from soil by enrichment culture technique at 60 degrees C. At this temperature
N H Stoffers et al.
Food additives and contaminants, 20(4), 410-416 (2003-05-31)
Analytical methods for the determination of laurolactam--the monomer of nylon 12--as well as the cyclic dimer and trimer were established. High performance liquid chromatography using ultraviolet (HPLC-UV) and mass spectrometric detection (HPLC-MS) were both found suitable to identify and quantify
Habiba Bougherara et al.
Journal of biomedical materials research. Part A, 82(1), 27-40 (2007-02-01)
A new biomimetic composite hip prosthesis (stem) was designed to obtain properties similar to those of the contiguous bone, in particular stiffness, to allow normal loading of the surrounding femoral bone. This normal loading would reduce excessive stress shielding, known
K R Williams et al.
Biomaterials, 8(4), 254-258 (1987-07-01)
Implantation of three different polymeric composite materials in the rat middle ear showed that the nylon prosthesis was encapsulated more rapidly than the two poly(methyl methacrylate) based implants. Several PMMA based implants were only partially covered at the 6 mnth
N H Stoffers et al.
Food additives and contaminants, 20(10), 949-959 (2003-11-05)
The migration of laurolactam and cyclic di- and trimer of nylon 12 was assessed using three different films and five food simulants (olive oil, isooctane, 95% ethanol, 50% ethanol, water). Substitute test conditions for migration into olive oil according to

Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..

Obraťte se na technický servis.