Přejít k obsahu
Merck
Všechny fotografie(2)

Hlavní dokumenty

167746

Sigma-Aldrich

3-Nitrobenzonitrile

98%

Přihlásitk zobrazení cen stanovených pro organizaci a smluvních cen


About This Item

Lineární vzorec:
O2NC6H4CN
Číslo CAS:
Molekulová hmotnost:
148.12
Beilstein/REAXYS Number:
637674
EC Number:
MDL number:
UNSPSC Code:
12352100
PubChem Substance ID:
NACRES:
NA.22

Quality Level

assay

98%

form

solid

mp

114-117 °C (lit.)

functional group

nitrile
nitro

SMILES string

[O-][N+](=O)c1cccc(c1)C#N

InChI

1S/C7H4N2O2/c8-5-6-2-1-3-7(4-6)9(10)11/h1-4H

InChI key

RUSAWEHOGCWOPG-UHFFFAOYSA-N

Hledáte podobné produkty? Navštivte Průvodce porovnáváním produktů

Application

3-Nitrobenzonitrile was employed as matrix for matrix assisted ionization vacuum method for mass spectrometery.

pictograms

Exclamation mark

signalword

Warning

Hazard Classifications

Acute Tox. 4 Oral

Storage Class

11 - Combustible Solids

wgk_germany

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

dust mask type N95 (US), Eyeshields, Gloves


Vyberte jednu z posledních verzí:

Osvědčení o analýze (COA)

Lot/Batch Number

Nevidíte správnou verzi?

Potřebujete-li konkrétní verzi, můžete vyhledat daný certifikát podle čísla dávky nebo čísla šarže.

Již tento produkt vlastníte?

Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.

Navštívit knihovnu dokumentů

Zákazníci si také prohlíželi

Sarah Trimpin et al.
Analytical chemistry, 85(4), 2005-2009 (2013-02-05)
Matrix assisted ionization vacuum (MAIV) is a new ionization method that does not require high voltages, a laser beam, or applied heat and depends only the proper matrix, 3-nitrobenzonitrile (3-NBN), and the vacuum of the mass spectrometer to initiate ionization.
Robert B Cody
Journal of the American Society for Mass Spectrometry, 29(8), 1594-1600 (2018-05-31)
Matrix-assisted ionization in vacuum (MAIV) was used to analyze the polyphenol content of ten different tea infusions. Nine different Camellia sinensis infusions were analyzed including three green teas, two black teas, two oolong teas, jasmine tea, and white tea. An
Bijay Banstola et al.
The Analyst, 142(10), 1672-1675 (2017-04-27)
We have developed a new ionization approach for matrix-assisted ionization with high temporal resolution using an electrically actuated pulsed valve. Matrix and analyte samples are deposited on a thin metal foil and placed at the inlet of an ambient ionization
Ellen D Inutan et al.
Molecular & cellular proteomics : MCP, 12(3), 792-796 (2012-12-18)
The introduction of electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) for the mass spectrometric analysis of peptides and proteins had a dramatic impact on biological science. We now report that a wide variety of compounds, including peptides, proteins, and
Yusuf Sert et al.
Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy, 107, 248-255 (2013-02-26)
In the present study, the experimental and theoretical harmonic and anharmonic vibrational frequencies of 4-chloro-3-nitrobenzonitrile were investigated. The experimental FT-IR (400-4000 cm(-1)) and μ-Raman spectra (100-4000 cm(-1)) of the molecule in the solid phase were recorded. Theoretical vibrational frequencies and

Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..

Obraťte se na technický servis.