Saltar al contenido
Merck

E3876

Sigma-Aldrich

N-Ethylmaleimide

crystalline, ≥98% (HPLC)

Sinónimos:

NEM

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Fórmula empírica (notación de Hill):
C6H7NO2
Número de CAS:
Peso molecular:
125.13
Beilstein/REAXYS Number:
112448
EC Number:
MDL number:
UNSPSC Code:
12352106
PubChem Substance ID:
NACRES:
NA.21

biological source

synthetic (organic)

Quality Level

assay

≥98% (HPLC)

form

crystalline

storage condition

(Tightly closed. Dry. Keep in a well-ventilated place. )

technique(s)

activity assay: suitable
co-immunoprecipitation (co-IP): suitable
immunoblotting: suitable

color

white to faint yellow

bp

210 °C (lit.)

mp

43-46 °C (lit.)

solubility

ethanol: 50 mg/mL, clear to slightly hazy, colorless to faint yellow or tan

suitability

suitable for Western blot

application(s)

life science and biopharma

storage temp.

2-8°C

SMILES string

CCN1C(=O)C=CC1=O

InChI

1S/C6H7NO2/c1-2-7-5(8)3-4-6(7)9/h3-4H,2H2,1H3

InChI key

HDFGOPSGAURCEO-UHFFFAOYSA-N

¿Está buscando productos similares? Visita Guía de comparación de productos

Application

Reagent for the covalent modification of cysteine residues in proteins.

Biochem/physiol Actions

Augments currents from native M-channels in sympathetic neurons and acts as an opener for KCNQ2, KCNQ4 and KCNQ5 channels.
Sulfhydryl alkylating agent that inactivates NADP-dependent isocitrate dehydrogenase and many endonucleases.

Preparation Note

NEM gives a clear solution in ethanol at 50 mg/ml. NEM dissolves in water (>50 mg in 4 ml); however, aqueous solutions are unstable. The rate of hydrolysis is pseudo-first order and significantly dependent on pH.

Other Notes

For additional information on our range of Biochemicals, please complete this form.

comparable product

Referencia del producto
Descripción
Precios

pictograms

Skull and crossbonesCorrosion

signalword

Danger

Hazard Classifications

Acute Tox. 2 Oral - Acute Tox. 3 Dermal - Eye Dam. 1 - Skin Corr. 1B - Skin Sens. 1

Storage Class

6.1A - Combustible acute toxic Cat. 1 and 2 / very toxic hazardous materials

wgk_germany

WGK 3

flash_point_f

163.2 °F - closed cup

flash_point_c

72.9 °C - closed cup

ppe

Eyeshields, Faceshields, Gloves, type P3 (EN 143) respirator cartridges


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Tatsuki Kurokawa et al.
Biochimica et biophysica acta, 1838(1 Pt B), 382-387 (2013-10-22)
Hv1 (also named, voltage-sensor only protein, VSOP) lacks an authentic pore domain, and its voltage sensor domain plays both roles in voltage sensing and proton permeation. The activities of a proton channel are intrinsic to protomers of Hv1, while Hv1
Nicolas Matuszak et al.
Journal of medicinal chemistry, 52(23), 7410-7420 (2009-07-09)
The endocannabinoid 2-arachidonoylglycerol (2-AG) plays a major role in many physiological processes, and its action is quickly terminated via enzymatic hydrolysis catalyzed by monoglyceride lipase (MGL). Regulating its endogenous level could offer therapeutic opportunities; however, few selective MGL inhibitors have
Hannah E Boycott et al.
Proceedings of the National Academy of Sciences of the United States of America, 110(41), E3955-E3964 (2013-09-26)
Atrial myocytes are continuously exposed to mechanical forces including shear stress. However, in atrial myocytes, the effects of shear stress are poorly understood, particularly with respect to its effect on ion channel function. Here, we report that shear stress activated
Marc Cuesta et al.
FASEB journal : official publication of the Federation of American Societies for Experimental Biology, 29(4), 1360-1370 (2014-12-17)
In humans, shift work induces a desynchronization between the circadian system and the outside world, which contributes to shift work-associated medical disorders. Using a simulated night shift experiment, we previously showed that 3 d of bright light at night fully
Julia Kuligowski et al.
Talanta, 127, 181-190 (2014-06-11)
Liquid chromatography-mass spectrometry (LC-MS) has been increasingly used in biomedicine to study the dynamic metabolomic responses of biological systems under different physiological or pathological conditions. To obtain an integrated snapshot of the system, metabolomic methods in biomedicine typically analyze biofluids

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico