Passa al contenuto
Merck
Tutte le immagini(1)

Documenti fondamentali

440191

Sigma-Aldrich

Hexamethyldisilazane

reagent grade, ≥99%

Sinonimo/i:

Bis(trimethylsilyl)amine, HMDS

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali

Scegli un formato

100 ML
CHF 91.10
1 L
CHF 420.00

CHF 91.10


Check Cart for Availability

Richiedi un ordine bulk

Scegli un formato

Cambia visualizzazione
100 ML
CHF 91.10
1 L
CHF 420.00

About This Item

Formula condensata:
(CH3)3SiNHSi(CH3)3
Numero CAS:
Peso molecolare:
161.39
Beilstein:
635752
Numero CE:
Numero MDL:
Codice UNSPSC:
12352103
ID PubChem:
NACRES:
NA.23

CHF 91.10


Check Cart for Availability

Richiedi un ordine bulk

Grado

reagent grade

Livello qualitativo

Saggio

≥99%

Stato

liquid

Indice di rifrazione

n20/D 1.407 (lit.)

P. ebollizione

125 °C (lit.)

Stringa SMILE

C[Si](C)(C)N[Si](C)(C)C

InChI

1S/C6H19NSi2/c1-8(2,3)7-9(4,5)6/h7H,1-6H3
FFUAGWLWBBFQJT-UHFFFAOYSA-N

Cerchi prodotti simili? Visita Guida al confronto tra prodotti

Descrizione generale

Hexamethyldisilane (HMDS) is a stable and effectivereagent for trimethylsilylation of hydrogen-labile substrates such as alcohols,amines, and carboxylic acids. It is commonly used for the protection of sensitivefunctional groups during chemical synthesis. Owing to its low cost, high vapor pressure, and safety, itis widely used as a precursor in chemical vapor deposition(CVD) reactions.

Applicazioni

Hexamethyldisilane (HMDS) can be used:
  • As a silylating agent in the trimethylsilylation of alcohols under nearly neutral reaction conditions.
  • To control the molecular weights of polypeptides during ring-opening polymerization of α-amino acid N-carboxyanhydrides.
  • To fabricate silicon carbonitride thin films by plasma-enhanced CVD.
  • For specimen preparation for scanning electron microscopy and the preparation of trimethylsilyl ethers from hydroxy compounds.

Caratteristiche e vantaggi

  • High chemicalstability and low molecular weight
  • Nontoxic andcost-effective reagent
  • Ammonia is theonly byproduct generated during silylation
  • Silylationreaction using HDMS is nearly neutral and does not need any precaution

Pittogrammi

FlameSkull and crossbones

Avvertenze

Danger

Indicazioni di pericolo

Classi di pericolo

Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 3 - Flam. Liq. 2

Codice della classe di stoccaggio

3 - Flammable liquids

Classe di pericolosità dell'acqua (WGK)

WGK 2

Punto d’infiammabilità (°F)

52.5 °F - closed cup

Punto d’infiammabilità (°C)

11.4 °C - closed cup

Dispositivi di protezione individuale

Faceshields, Gloves, Goggles, type ABEK (EN14387) respirator filter


Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

Non trovi la versione di tuo interesse?

Se hai bisogno di una versione specifica, puoi cercare il certificato tramite il numero di lotto.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

I clienti hanno visto anche

F Braet et al.
Journal of microscopy, 186(Pt 1), 84-87 (1997-04-01)
Critical point drying (CPD) is a common method of drying biological specimens for scanning electron microscopy (SEM). Drying by evaporation of hexamethyldisilazane (HMDS) has been described as a good alternative. This method, however, is infrequently used. Therefore, we reassessed HMDS
Rapid and highly efficient trimethylsilylation of alcohols and phenols
with hexamethyldisilazane (HMDS) catalysed by in situ generated I2
using OxoneR /KI or cerium ammonium nitrate (CAN)/KI systems
under mild conditions
Eskandar K, et al.
Journal of Chemical Sciences (Bangalore), 123(5), 703-708 (2011)
Judith J de Vries et al.
International journal of molecular sciences, 21(19) (2020-10-01)
Subjects with diabetes mellitus (DM) have an increased risk of arterial thrombosis, to which changes in clot structure and mechanics may contribute. Another contributing factor might be an increased formation of neutrophil extracellular traps (NETs) in DM. NETs are mainly
Clyde Savio Pinto et al.
Scientific reports, 9(1), 12191-12191 (2019-08-23)
Apical projections are integral functional units of epithelial cells. Microvilli and stereocilia are cylindrical apical projections that are formed of bundled actin. Microridges on the other hand, extend laterally, forming labyrinthine patterns on surfaces of various kinds of squamous epithelial
Teresa Dean et al.
Biomaterials science, 8(11), 3078-3094 (2020-04-30)
Cancer associated fibroblasts (CAFs) are a major cellular component of the tumour stroma and have been shown to promote tumour cell invasion and disease progression. CAF-cancer cell interactions are bi-directional and occur via both soluble factor dependent and extracellular matrix

Articoli

atomic layer deposition (ALD), microelectronics, Mo:Al2O3 films, nanocomposite coating, photovoltaics, semiconductor devices, W:Al2O3 films, composite films, layer-by-layer

Spintronics offer breakthroughs over conventional memory/logic devices with lower power, leakage, saturation, and complexity.

Synthesis of Melting Gels Using Mono-Substituted and Di-Substituted Alkoxysiloxanes

The properties of many devices are limited by the intrinsic properties of the materials that compose them.

Questions

1–3 of 3 Questions  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  3. What is the storage temperature of this reagent?

    1 answer
    1. This product may be stored at room temperature. For products with no specified storage temperature given on the label or product page, ambient storage may be assumed. Products that require controlled temperature storage, such as refrigeration or freezer conditions, storage temperatures are published on the product label, Certificate of Analysis, the Safety Data Sheet (SDS).

      Helpful?

Reviews

No rating value

Active Filters

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.