Direkt zum Inhalt
Merck
  • Determination of manganese- and manganese-containing fungicides with lucigenin-Tween-20-enhanced chemiluminescence detection.

Determination of manganese- and manganese-containing fungicides with lucigenin-Tween-20-enhanced chemiluminescence detection.

Luminescence : the journal of biological and chemical luminescence (2015-02-03)
Mohammad Yaqoob, Mohammad Asghar, Abdul Nabi
ZUSAMMENFASSUNG

A flow-injection (FI) method is reported for the determination of Mn(II), maneb and mancozeb fungicides based on the catalytic effect of Mn(II) on the oxidation of lucigenin and dissolved oxygen in a basic solution. The Tween-20 surfactant has been reported for first time to enhance lucigenin chemiluminescence (CL) intensity in the presence of Mn(II) (53%) and maneb and mancozeb (89%). The calibration graphs were linear in the concentration range of 0.001-1.5 mg L(-1) (R(2) = 0.9982 (n = 11) with a limit of detection (S/N = 3) of 0.1 µg L(-1) for Mn(II) and 0.01-3.0 mg L(-1) [R(2) = 0.9989 and R(2) = 0.9992 (n = 6)] with a limit of detection (S/N =3) of 1.0 µg L(-1) for maneb and mancozeb respectively. Injection throughputs of 90 and 120 h(-1) for Mn(II) and maneb and mancozeb respectively, and relative standard deviations of 1.0-3.4% were obtained in the concentration range studied. The experimental variables, e.g., reagents concentrations, flow rates, sample volume, and photomultiplier tube voltage, were optimized and potential interferences were investigated. The analysis of Mn(II) in river water reference materials (SLRS-4 and SLRS-5) showed good agreement with the certified values incorporating an on-line 8-hydroxyquinoline chelating column in the manifold for removing interfering metal ions. Recoveries for maneb and mancozeb were in the range of 92 ± 5 to 104 ± 3% and 91 ± 2 to 100 ± 4% (n = 3) respectively. The effect of 30 other pesticides (fungicides, herbicides and insecticides) was also examined in the lucigenin-Tween-20 CL system.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Sigma-Aldrich
Salzsäure, ACS reagent, 37%
Sigma-Aldrich
Salpetersäure, ACS reagent, 70%
Sigma-Aldrich
Salzsäure, ACS reagent, 37%
Sigma-Aldrich
Chlorwasserstoff -Lösung, 4.0 M in dioxane
Sigma-Aldrich
Natriumdodecylsulfat, BioReagent, suitable for electrophoresis, for molecular biology, ≥98.5% (GC)
Sigma-Aldrich
Hexadecyltrimethylammoniumbromid, ≥98%
Sigma-Aldrich
Natriumdodecylsulfat, ≥99.0% (GC), dust-free pellets
Sigma-Aldrich
Salpetersäure, 70%, purified by redistillation, ≥99.999% trace metals basis
Sigma-Aldrich
Salzsäure -Lösung, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
Hexadecyltrimethylammoniumbromid, for molecular biology, ≥99%
Sigma-Aldrich
Natriumdodecylsulfat -Lösung, BioUltra, for molecular biology, 10% in H2O
Sigma-Aldrich
Salzsäure, 37 wt. % in H2O, 99.999% trace metals basis
Sigma-Aldrich
Salzsäure, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., fuming, ≥37%, APHA: ≤10
Sigma-Aldrich
Salzsäure, meets analytical specification of Ph. Eur., BP, NF, fuming, 36.5-38%
Sigma-Aldrich
Salzsäure, 36.5-38.0%, BioReagent, for molecular biology
Sigma-Aldrich
Chlorwasserstoff -Lösung, 2.0 M in diethyl ether
Sigma-Aldrich
Salpetersäure, puriss. p.a., reag. ISO, reag. Ph. Eur., for determinations with dithizone, ≥65%
Sigma-Aldrich
Salpetersäure, puriss. p.a., 65.0-67.0%
Sigma-Aldrich
Natriumdodecylsulfat, ACS reagent, ≥99.0%
Sigma-Aldrich
Natriumdodecylsulfat -Lösung, BioUltra, for molecular biology, 20% in H2O
Sigma-Aldrich
Natriumdodecylsulfat, ReagentPlus®, ≥98.5% (GC)
Supelco
Salzsäure -Lösung, volumetric, 0.1 M HCl (0.1N), endotoxin free
Sigma-Aldrich
Hexadecyltrimethylammoniumbromid, BioXtra, ≥99%
Sigma-Aldrich
Natriumdodecylsulfat, BioUltra, for molecular biology, ≥99.0% (GC)
Sigma-Aldrich
Salpetersäure, puriss. p.a., ≥65% (T)
Sigma-Aldrich
Chlorwasserstoff -Lösung, 1.0 M in diethyl ether
Sigma-Aldrich
Chlorwasserstoff, ReagentPlus®, ≥99%
Sigma-Aldrich
Salpetersäure, red, fuming, HNO3 >90 %
Sigma-Aldrich
Salzsäure, puriss., 24.5-26.0%
Supelco
Natriumdodecylsulfat, dust-free pellets, suitable for electrophoresis, for molecular biology, ≥99.0% (GC)