  • Mass spectrometric behavior of anabolic androgenic steroids using gas chromatography coupled to atmospheric pressure chemical ionization source. Part I: ionization.

Mass spectrometric behavior of anabolic androgenic steroids using gas chromatography coupled to atmospheric pressure chemical ionization source. Part I: ionization.

Journal of mass spectrometry : JMS (2014-06-11)
M Raro, T Portolés, J V Sancho, E Pitarch, F Hernández, J Marcos, R Ventura, C Gómez, J Segura, O J Pozo
ZUSAMMENFASSUNG

The detection of anabolic androgenic steroids (AAS) is one of the most important topics in doping control analysis. Gas chromatography coupled to (tandem) mass spectrometry (GC-MS(/MS)) with electron ionization and liquid chromatography coupled to tandem mass spectrometry have been traditionally applied for this purpose. However, both approaches still have important limitations, and, therefore, detection of all AAS is currently afforded by the combination of these strategies. Alternative ionization techniques can minimize these drawbacks and help in the implementation of a single method for the detection of AAS. In the present work, a new atmospheric pressure chemical ionization (APCI) source commercialized for gas chromatography coupled to a quadrupole time-of-flight analyzer has been tested to evaluate the ionization of 60 model AAS. Underivatized and trimethylsylil (TMS)-derivatized compounds have been investigated. The use of GC-APCI-MS allowed for the ionization of all AAS assayed irrespective of their structure. The presence of water in the source as modifier promoted the formation of protonated molecules ([M+H](+)), becoming the base peak of the spectrum for the majority of studied compounds. Under these conditions, [M+H](+), [M+H-H2O](+) and [M+H-2·H2O](+) for underivatized AAS and [M+H](+), [M+H-TMSOH](+) and [M+H-2·TMSOH](+) for TMS-derivatized AAS were observed as main ions in the spectra. The formed ions preserve the intact steroid skeleton, and, therefore, they might be used as specific precursors in MS/MS-based methods. Additionally, a relationship between the relative abundance of these ions and the AAS structure has been established. This relationship might be useful in the structural elucidation of unknown metabolites.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Sigma-Aldrich
2-Mercaptoethanol, for molecular biology, suitable for electrophoresis, suitable for cell culture, BioReagent, 99% (GC/titration)
Sigma-Aldrich
2-Mercaptoethanol, ≥99.0%
Sigma-Aldrich
2-Mercaptoethanol, BioUltra, for molecular biology, ≥99.0% (GC)
Sigma-Aldrich
Essigsäureanhydrid, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99% (GC)
Sigma-Aldrich
Essigsäureanhydrid, ReagentPlus®, ≥99%
Sigma-Aldrich
Ammoniumiodid, ACS reagent, ≥99%
Sigma-Aldrich
Essigsäureanhydrid, 99.5%
Sigma-Aldrich
Testosteron, purum, ≥99.0% (HPLC)
Supelco
Testosterone solution, 1.0 mg/mL in acetonitrile, ampule of 1 mL, certified reference material, Cerilliant®
Sigma-Aldrich
Essigsäureanhydrid, ACS reagent, ≥98.0%
Supelco
N-Methyl-bis-trifluoracetamid, for GC derivatization, LiChropur, ≥97.0% (GC)
Sigma-Aldrich
Ammoniumiodid, 99.999% trace metals basis
Sigma-Aldrich
17α-Methyltestosteron, ≥97.0% (HPLC)
Supelco
2-Mercaptoethanol, for HPLC derivatization, LiChropur, ≥99.0% (GC)
Sigma-Aldrich
Essigsäureanhydrid, Arxada quality, ≥99.5% (GC)
Sigma-Aldrich
Ethisteron, ≥99% (HPLC)
Supelco
Essigsäureanhydrid, for GC derivatization, LiChropur, ≥99.0%
Supelco
N-Methyl-bis-trifluoracetamid, for GC derivatization, LiChropur, ≥99.0% (GC)
Supelco
4-Androsten-3,17-dion, VETRANAL®, analytical standard
Supelco
17α-Methyltestosteron, VETRANAL®, analytical standard
Testosteron, European Pharmacopoeia (EP) Reference Standard
Supelco
Testosteron, VETRANAL®, analytical standard
Supelco
17β-Hydroxy-17-methyl-androsta-1,4-dien-3-on, analytical standard
Methyltestosteron, European Pharmacopoeia (EP) Reference Standard
Methyltestosteron für die Systemeignung, European Pharmacopoeia (EP) Reference Standard