Direkt zum Inhalt
Merck
  • Analysis of methanol or formic acid in body fluids by headspace solid-phase microextraction and capillary gas chromatography.

Analysis of methanol or formic acid in body fluids by headspace solid-phase microextraction and capillary gas chromatography.

Journal of chromatography. B, Biomedical sciences and applications (1999-11-26)
X P Lee, T Kumazawa, K Kondo, K Sato, O Suzuki
ZUSAMMENFASSUNG

Methanol and its metabolite formic acid have been found extractable from human whole blood and urine by headspace solid-phase microextraction (SPME) with a Carboxen/polydimethylsiloxane fiber. The headspace SPME for formic acid was carried out after derivatization to methyl formate under acidic conditions. The determinations of both compounds were made by using acetonitrile as internal standard (IS) and capillary gas chromatography (GC) with flame ionization detection. The headspace SPME-GC gave sharp peaks for methanol, methyl formate and I.S.; and low background noises for whole blood and urine samples. Extraction efficiencies were 0.25-1.05% of methanol and 0.38-0.84% formic acid for whole blood and urine. The calibration curves for methanol and formic acid showed excellent linearity in the range of 1.56 to 800 and 1.56 to 500 microg/0.5 ml of whole blood or urine, respectively. The detection limits were 0.1-0.5 microg/0.5 ml for methanol and 0.6 microg/0.5 ml for formic acid for both body fluids. The within-day relative standard deviations in terms of extraction efficiency for both compounds in whole blood and urine samples were not greater than 9.8%. By using the established SPME method, methanol and formic acid were successfully separated and determined in rat blood after oral administration of methanol.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Sigma-Aldrich
Methanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Methanol, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
Methanol, Laboratory Reagent, ≥99.6%
Supelco
SPME-Faseranordnung Divinylbenzol/Carboxen/Polydimethylsiloxan (DVB/CAR/PDMS), needle size 24 ga, StableFlex
Sigma-Aldrich
Methanol, ACS spectrophotometric grade, ≥99.9%
Supelco
SPME-Faseranordnung Divinylbenzol/Carboxen/Polydimethylsiloxan (DVB/CAR/PDMS), needle size 24 ga, for use with manual holder
Supelco
SPME-Faseranordnung Divinylbenzol/Carboxen/Polydimethylsiloxan (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with autosampler
Sigma-Aldrich
Methanol, BioReagent, ≥99.93%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, Absolute - Acetone free
Supelco
SPME-Faseranordnung Divinylbenzol/Carboxen/Polydimethylsiloxan (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with manual holder or autosampler, fiber L 2 cm
Supelco
SPME-Faseranordnung Divinylbenzol/Carboxen/Polydimethylsiloxan (DVB/CAR/PDMS), needle size 24 ga, StableFlex, for use with autosampler
Supelco
ORBO Carboxen-564 Röhrchen, W,F,F separators, O.D. × L 6 mm × 75 mm, pkg of 25 ea, for analyte group MEK (methylethyl ketone)
Supelco
ORBO 78 HBr auf Carboxen® 564 speziell gereinigt (20/45), 400/200 mg, W,W,W separators, O.D. × L 6 mm × 110 mm, pkg of 25 ea
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Supelco
Carboxen®-1010 PLOT Kapillar-GC-Säule, L × I.D. 30 m × 0.53 mm, average thickness 30 μm
Supelco
SPME-Faseranordnung Carboxen/Polydimethylsiloxan (CAR/PDMS), df 75 μm(CAR/PDMS, for use with manual holder, needle size 24 ga
Supelco
Carboxen® Adsorptionsmittel, matrix Carboxen® 1000, 60-80 mesh, bottle of 10 g
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Supelco
Carboxen®-1006 PLOT Kapillar-GC-Säule, L × I.D. 30 m × 0.53 mm, average thickness 30 μm
Supelco
SPME-Faseranordnung Carboxen/Polydimethylsiloxan (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPME-Faseranordnung Carboxen/Polydimethylsiloxan (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 23 ga, StableFlex, for use with autosampler
Sigma-Aldrich
Methanol, puriss., meets analytical specification of Ph Eur, ≥99.7% (GC)
Supelco
SPME-Faseranordnung Carboxen/Polydimethylsiloxan (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 24 ga, for use with autosampler
Supelco
Carboxen®-1010 PLOT Kapillar-GC-Säule, L × I.D. 30 m × 0.32 mm, average thickness 15 μm
Supelco
SPME-Faseranordnung Carboxen/Polydimethylsiloxan (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, for use with manual holder, StableFlex fiber