Direkt zum Inhalt
Merck

A9202

Sigma-Aldrich

Angiotensin Fragment 1-7 acetate salt hydrate

≥90% (HPLC), powder, RAS heptapeptide

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise

Größe auswählen

1 MG
CHF 87.30
5 MG
CHF 267.00

CHF 87.30


Check Cart for Availability

Bulk-Bestellung anfordern

Größe auswählen

Ansicht ändern
1 MG
CHF 87.30
5 MG
CHF 267.00

About This Item

Empirische Formel (Hill-System):
C41H62N12O11 · xC2H4O2 · yH2O
Molekulargewicht:
899.00 (anhydrous free base basis)
MDL-Nummer:
UNSPSC-Code:
12352202
PubChem Substanz-ID:
NACRES:
NA.77

CHF 87.30


Check Cart for Availability

Bulk-Bestellung anfordern

Produktbezeichnung

Angiotensin Fragment 1-7 acetate salt hydrate, ≥90% (HPLC), powder

Qualitätsniveau

Assay

≥90% (HPLC)

Form

powder

UniProt-Hinterlegungsnummer

Lagertemp.

−20°C

SMILES String

CCC(C)C(NC(=O)C(Cc1ccc(O)cc1)NC(=O)C(NC(=O)C(CCCNC(N)=N)NC(=O)C(N)CC(O)=O)C(C)C)C(=O)NC(Cc2cnc[nH]2)C(=O)N3CCCC3C(O)=O

InChI

1S/C41H62N12O11/c1-5-22(4)33(38(61)50-29(17-24-19-45-20-47-24)39(62)53-15-7-9-30(53)40(63)64)52-36(59)28(16-23-10-12-25(54)13-11-23)49-37(60)32(21(2)3)51-35(58)27(8-6-14-46-41(43)44)48-34(57)26(42)18-31(55)56/h10-13,19-22,26-30,32-33,54H,5-9,14-18,42H2,1-4H3,(H,45,47)(H,48,57)(H,49,60)(H,50,61)(H,51,58)(H,52,59)(H,55,56)(H,63,64)(H4,43,44,46)

InChIKey

PVHLMTREZMEJCG-UHFFFAOYSA-N

Angaben zum Gen

human ... AGT(183)

Amino Acid Sequence

Asp-Arg-Val-Tyr-Ile-His-Pro

Anwendung

Angiotensin Fragment 1-7 acetate salt hydrate has been used:
  • to evaluate its effects on a rat model of ventilator-induced diaphragmatic dysfunction (VIDD) with neuromuscular blocking agent infusion[1]
  • to unilaterally inject into the lateral preoptic area (LPA) to study its effects on intravesical pressure, arterial pressure, heart rate, and renal conductance in the female rats[2]
  • to study its association with influenza A virus (IAV) infection[3]

Biochem./physiol. Wirkung

Angiotensin fragment 1-7 is a biologically active heptapeptide of the renin-angiotensin system (RAS).[3] It is associated with anti-inflammatory and anti-fibrotic effects in many inflammatory diseases such as asthma, dyslipidemia, renal injury, arthritis, and lung fibrosis. Angiotensin fragment 1-7 acts as a pro-resolving mediator and induces resolution of inflammation via Mas receptor (MasR).[3] It is responsible for relaxation in several vascular beds. Angiotensin fragment 1-7 has a dual action of an angiotensin II type 1 (AT1) receptor agonist and antagonist depending on the presence of angiotensin II. It also serves as a substrate for angiotensin-converting enzyme (ACE). Sometimes, angiotensin fragment 1-7 prevents ACE activity leading to decreased angiotensin II generation and improved bradykinin-induced vasodilatation.[4]

Sonstige Hinweise

Lyophilized from 0.5% acetic acid

Lagerklassenschlüssel

11 - Combustible Solids

WGK

WGK 3

Flammpunkt (°F)

Not applicable

Flammpunkt (°C)

Not applicable

Persönliche Schutzausrüstung

Eyeshields, Gloves, type N95 (US)


Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Die passende Version wird nicht angezeigt?

Wenn Sie eine bestimmte Version benötigen, können Sie anhand der Lot- oder Chargennummer nach einem spezifischen Zertifikat suchen.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Eliza M Melo et al.
Pharmacological research, 163, 105292-105292 (2020-11-11)
Resolution failure of exacerbated inflammation triggered by Influenza A virus (IAV) prevents return of pulmonary homeostasis and survival, especially when associated with secondary pneumococcal infection. Therapeutic strategies based on pro-resolving molecules have great potential against acute inflammatory diseases. Angiotensin-(1-7) [Ang-(1-7)]
Vanessa Zambelli et al.
Intensive care medicine experimental, 7(1), 8-8 (2019-01-20)
Ventilator-induced diaphragmatic dysfunction (VIDD) is a common event during mechanical ventilation (MV) leading to rapid muscular atrophy and contractile dysfunction. Recent data show that renin-angiotensin system is involved in diaphragmatic skeletal muscle atrophy after MV. In particular, angiotensin-II can induce
S Y Osei et al.
European journal of pharmacology, 234(1), 35-42 (1993-03-30)
Regional vascular responses to angiotensin (Ang)-(1-7), a heptapeptide derivative of Ang II were investigated in the feline hindquarters and mesenteric vascular beds under conditions of controlled flow. In the mesenteric vascular bed, injections of Ang-(1-7) in doses of 1, 3
C Caruso-Neves et al.
Biochimica et biophysica acta, 1467(1), 189-197 (2000-08-10)
Angiotensin-(1-7) (Ang-(1-7)) modulates the Na+-ATPase, but not the Na+,K+-ATPase activity present in pig kidney proximal tubules. The Na+-ATPase, insensitive to ouabain, but sensitive to furosemide, is stimulated by Ang-(1-7) (68% by 10(-9) M), in a dose-dependent manner. This effect is
Joep H M van Esch et al.
European journal of pharmacology, 588(2-3), 286-293 (2008-05-31)
Aminopeptidases metabolize angiotensin II to angiotensin-(2-8) (=angiotensin III) and angiotensin-(3-8) (=angiotensin IV), and carboxypeptidases generate angiotensin-(1-7) from angiotensin I and II. Angiotensin-converting enzyme (ACE) inhibitors and/or angiotensin II type 1 (AT1) receptor blockers affect the concentrations of these metabolites, and

Questions

  1. For how long can Angiotensin 1-7 (A9202) be stored at -20?

    1 answer
    1. This product is not assigned an expiration date. It contains a recommended retest date of approximately 5 years after the quality release date. A recommended retest date is the period of time during which the product is expected to remain within established stability specifications, provided that it has been stored under defined conditions. After the Retest Date, product samples should be examined to ensure that the product is still in compliance with the established specifications. For more information, you may access the "Product Dating Information" document under "ADDITIONAL USEFUL DOCUMENTS ABOUT OUR PRODUCTS" at the bottom of the Quality Services page with this link: https://www.sigmaaldrich.com/US/en/life-science/quality-and-regulatory-management/quality-services.

      Helpful?

Reviews

No rating value

Active Filters

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.