NIST1951C
Lipide in gefrorenem Humanserum
NIST® SRM® 1951c
Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise
Alle Fotos(1)
About This Item
Empfohlene Produkte
Qualität
certified reference material
Qualitätsniveau
Form
liquid
Verpackung
pkg of 4 vials (2 ea conc)
Hersteller/Markenname
NIST®
Methode(n)
mass spectrometry (MS): suitable
Anwendung(en)
clinical testing
Format
matrix material
Verwandte Kategorien
Allgemeine Beschreibung
A unit of SRM1951C consists of four vials of frozen human serum, two vials each at two different analyte concentration levels. Each bottle contains approximately 1 mL of serum.
NIST1951C_Cert
NIST1951C_SDS
NIST1951C_Cert
NIST1951C_SDS
Anwendung
The lipids in frozen human serum are a standard reference material (SRM) that is used for evaluating the accuracy of clinical procedures for the determination of total cholesterol, high-density lipoprotein (HDL)-cholesterol, low-density lipoprotein (LDL)-cholesterol, and total glycerides in human serum. It is also used for validating working or secondary reference materials.
Sonstige Hinweise
- Details on expiration, storage, safety, usage, and source are provided in the NIST certificate.
- Notes on biomaterials, disposal, and transport are documented in SDS.
Certified for the analytes listed below.
Total Cholesterol, Total Glycerides
Reference/Informational value is provided for the following analytes.
HDL-Cholesterol, LDL-Cholesterol, Total Cholesterol
See certificate for values and more details at nist.gov/SRM.
Total Cholesterol, Total Glycerides
Reference/Informational value is provided for the following analytes.
HDL-Cholesterol, LDL-Cholesterol, Total Cholesterol
See certificate for values and more details at nist.gov/SRM.
Angaben zur Herstellung
- The serum is shipped frozen on dry ice and after receiving it should be frozen until ready for use.
- Before use, the bottles must be thawed to room temperature.
- The certified concentrations apply only to serum thawed to room temperature, 20 °C to 25 °C.
Rechtliche Hinweise
NIST is a registered trademark of National Institute of Standards and Technology
SRM is a registered trademark of National Institute of Standards and Technology
Ähnliches Produkt
Produkt-Nr.
Beschreibung
Preisangaben
Lagerklassenschlüssel
12 - Non Combustible Liquids
WGK
WGK 1
Flammpunkt (°F)
Not applicable
Flammpunkt (°C)
Not applicable
Choose from one of the most recent versions:
Analysenzertifikate (COA)
Sorry, we don't have COAs for this product available online at this time.
If you need assistance, please contact Kundensupport
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Kunden haben sich ebenfalls angesehen
Analytical chemistry, 90(20), 11962-11971 (2018-09-14)
We report an extensive 600 MHz NMR trial of quantitative lipoprotein and small-molecule measurements in human blood serum and plasma. Five centers with eleven 600 MHz NMR spectrometers were used to analyze 98 samples including 20 quality controls (QCs), 37
The extended lipid panel assay: a clinicallydeployed high-throughput nuclear magnetic resonance method for the simultaneous measurement of lipids and Apolipoprotein B
Adv. in Lipids Research (2020)
Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..
Setzen Sie sich mit dem technischen Dienst in Verbindung.