Direkt zum Inhalt
Merck

62118

Supelco

(R)-(+)-Limone

analytical standard

Synonym(e):

(+)-p-Mentha-1,8-dien, (+)-Carven, (R)-4-Isopropenyl-1-methyl-1-cyclohexen

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise

Größe auswählen

1 ML
CHF 63.40
5 ML
CHF 192.00
25 ML
CHF 777.00

CHF 63.40


Check Cart for Availability

Bulk-Bestellung anfordern

Größe auswählen

Ansicht ändern
1 ML
CHF 63.40
5 ML
CHF 192.00
25 ML
CHF 777.00

About This Item

Empirische Formel (Hill-System):
C10H16
CAS-Nummer:
Molekulargewicht:
136.23
Beilstein:
2204754
EG-Nummer:
MDL-Nummer:
UNSPSC-Code:
85151701
PubChem Substanz-ID:
NACRES:
NA.24

CHF 63.40


Check Cart for Availability

Bulk-Bestellung anfordern

Qualität

analytical standard

Qualitätsniveau

Dampfdichte

4.7 (vs air)

Dampfdruck

<3 mmHg ( 14.4 °C)

Assay

≥99.0% (sum of enantiomers, GC)

Optische Aktivität

[α]20/D +115.5±1°, c = 10% in ethanol

Haltbarkeit

limited shelf life, expiry date on the label

Expl.-Gr.

6.1 %

Methode(n)

HPLC: suitable
gas chromatography (GC): suitable

Brechungsindex

n20/D 1.473 (lit.)
n20/D 1.473

bp

176-177 °C (lit.)

Dichte

0.842 g/mL at 20 °C (lit.)

Anwendung(en)

agriculture
cleaning products
cosmetics
environmental
flavors and fragrances
food and beverages
personal care

Format

neat

Lagertemp.

2-8°C

SMILES String

CC(=C)[C@@H]1CCC(C)=CC1

InChI

1S/C10H16/c1-8(2)10-6-4-9(3)5-7-10/h4,10H,1,5-7H2,2-3H3/t10-/m0/s1

InChIKey

XMGQYMWWDOXHJM-JTQLQIEISA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Allgemeine Beschreibung

R)-(+)-Limonene is the R- and the predominant enantiomer of the cyclic monoterpene, limonene. It is present as the major constituent of essential oils extracted from oranges, grapefruits, and lemons. In addition, it is also added as a flavoring agent in different personal and household cleaning products, beverages, and confectionery goods. It is known to possess antioxidant, antimicrobial, antifungal, anti-inflammatory, and anti-carcinogenic properties.[1][1]
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.

Anwendung

This analytical standard can also be used as follows:
  • Analysis of alcoholic beverages for the determination of (R)-(+)-limonene by differential pulse voltammetry (DPV) using two novel electrochemical sensors
  • Simultaneous determination of limonene and linalool in 10 perfume product samples by two-dimensional high-performance liquid chromatographic (HPLC) method combined with electrospray ionization tandem mass spectrometry (ESI-MS/MS)
  • Determination of the enantiomeric composition of volatile chiral compounds, commonly present in three plant species from the Citrus genus by multidimensional gas chromatography (MDGC) coupled to mass spectrometry (MS)
  • Multi-residue analysis of volatiles and fatty acids found in wild and cultivated fennel samples by a single extraction method and gas chromatographic-flame ionization detection (GC-FID)

Sonstige Hinweise

This compound is commonly found in plants of the genus: carum mentha salvia
Regioselektive Hydrierung der exozyklischen Doppelbindung[2][3]; Regioselektive Epoxidierung der endozyklischen Doppelbindung[4]

Anwendung

Produkt-Nr.
Beschreibung
Preisangaben

Signalwort

Danger

Gefahreneinstufungen

Aquatic Acute 1 - Aquatic Chronic 1 - Asp. Tox. 1 - Flam. Liq. 3 - Skin Irrit. 2 - Skin Sens. 1

Lagerklassenschlüssel

3 - Flammable liquids

WGK

WGK 2

Flammpunkt (°F)

123.8 °F - closed cup

Flammpunkt (°C)

51 °C - closed cup

Persönliche Schutzausrüstung

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Die passende Version wird nicht angezeigt?

Wenn Sie eine bestimmte Version benötigen, können Sie anhand der Lot- oder Chargennummer nach einem spezifischen Zertifikat suchen.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

R. Baker et al.
Journal of the Chemical Society. Chemical Communications, 414-414 (1987)
Whitefly attraction to rosemary (Rosmarinus officinialis L.) is associated with volatile composition and quantity
Sadeh D, et al.
PLoS ONE, 12(5) (2017)
Giuseppe Ferrandino et al.
Clinical and translational gastroenterology, 11(9), e00239-e00239 (2020-10-24)
Liver cirrhosis and its complication - hepatocellular carcinoma (HCC) - have been associated with increased exhaled limonene. It is currently unclear whether this increase is more strongly associated with the presence of HCC or with the severity of liver dysfunction.
Rebecca Jordan et al.
Neuron, 98(6), 1214-1228 (2018-06-05)
The olfactory bulb (OB) is the first site of synaptic odor information processing, yet a wealth of contextual and learned information has been described in its activity. To investigate the mechanistic basis of contextual modulation, we use whole-cell recordings to
T. Kitahara et al.
Tetrahedron, 43, 2689-2689 (1987)

Artikel

A throughput HS-SPME-GC-MS method to analyze volatile compounds in Perilla leaves at low extraction temperatures using four different SPME fibers.

Protokolle

GC Analysis of Sweet Orange Essential Oil on SLB®-5ms (10 m x 0.10 mm I.D., 0.10 μm), Fast GC Analysis

Verwandter Inhalt

Gas chromatography separates volatile compounds in the gas phase, applied in various industries for quality control.

Die Gaschromatographie ist eine häufig eingesetzte Analysentechnik, die zur Trennung und Analyse flüchtiger Verbindungen in der Gasphase verwendet wird. Die GC wird in vielen Industriezweigen zur Qualitätskontrolle und zur Identifizierung und/oder Quantifizierung von Verbindungen in einem Gemisch eingesetzt.

Chromatograms

suitable for GC

Questions

1–2 of 2 Questions  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.