Direkt zum Inhalt
Merck

1.06525

Supelco

Natriumiodat

for analysis EMSURE®

Synonym(e):

Natriumiodat

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Empirische Formel (Hill-System):
INaO3
CAS-Nummer:
Molekulargewicht:
197.89
MDL-Nummer:
UNSPSC-Code:
12352302
EG-Index-Nummer:
231-672-5
NACRES:
NA.21

Qualitätsniveau

Produktlinie

EMSURE®

Assay

≥99.5% (iodometric)

Form

solid

pH-Wert

5.8 (25 °C, 90 g/L in H2O)

Löslichkeit

81 g/L

Dichte

4.28 g/cm3 at 20 °C

Schüttdichte

1150 kg/m3

Anionenspuren

bromide, bromate, chloride, chlorate (as Cl-): ≤0.02%
iodide (I-): ≤0.002%
sulfate (SO42-): ≤0.005%

Kationenspuren

Cd: ≤0.00005%
Cu: ≤0.0001%
Fe: ≤0.001%
K: ≤0.02%
Mn: ≤0.00005%
N: ≤0.002%
Pb: ≤0.0002%
Zn: ≤0.0001%

Lagertemp.

2-30°C

InChI

1S/HIO3.Na/c2-1(3)4;/h(H,2,3,4);/q;+1/p-1

InChIKey

WTCBONOLBHEDIL-UHFFFAOYSA-M

Anwendung


  • Comparative Analysis of Molecular Landscape in Mouse Models and Patients Reveals Conserved Inflammation Pathways in Age-Related Macular Degeneration.: This study highlights the use of sodium iodate to induce retinal degeneration in mouse models to explore conserved inflammation pathways relevant to age-related macular degeneration. This model provides insights into potential therapeutic targets for inflammatory diseases of the retina (Liu et al., 2024).

  • The BET PROTAC inhibitor dBET6 protects against retinal degeneration and inhibits the cGAS-STING in response to light damage.: Sodium iodate was utilized to model retinal degeneration, showing the effectiveness of the BET PROTAC inhibitor dBET6 in protecting against retinal damage and modulating inflammatory responses, potentially offering new treatment avenues for retinal diseases (Zhu et al., 2023).

  • Sodium Iodate-Induced Degeneration Results in Local Complement Changes and Inflammatory Processes in Murine Retina.: This research delves into the specific inflammatory processes and complement system changes following sodium iodate-induced retinal degeneration in mice, providing a detailed molecular understanding of retinal inflammatory responses (Enzbrenner et al., 2021).

  • IL-33trap-mediated IL-33 neutralization does not exacerbate choroidal neovascularization, but fails to protect against retinal degeneration in a dry age-related macular degeneration model.: The study used sodium iodate to induce retinal degeneration and test IL-33 neutralization′s effectiveness in preventing retinal damage, contributing to the understanding of inflammatory pathways in retinal diseases (Van Hove et al., 2021).

  • An Acute Injury Model for the Phenotypic Characteristics of Geographic Atrophy.: Utilizing sodium iodate to create an acute retinal injury model, this study mimics the phenotypic characteristics of geographic atrophy, providing a valuable tool for studying this condition and testing potential treatments (Bhutto et al., 2018).

Hinweis zur Analyse

Gehalt (iodometrisch): ≥ 99,5 %
pH-Wert (5 %; Wasser): 5 - 8
Chlorid, Chlorat, Bromid, Bromat (als Cl): ≤ 0,02 %
Iodid (I): ≤ 0,002 %
Sulfat (SO₄): ≤ 0,005 %
Gesamtstickstoff (N): ≤ 0,002 %
Cd (Cadmium): ≤ 0,00005 %
Cu (Kupfer): ≤ 0,0001 %
Fe (Eisen): ≤ 0,001 %
K (Kalium): ≤ 0,02 %
Mn (Mangan): ≤ 0,00005 %
Pb (Blei): ≤ 0,0002 %
Zn (Zink): ≤ 0,0001 %

Rechtliche Hinweise

EMSURE is a registered trademark of Merck KGaA, Darmstadt, Germany

Signalwort

Danger

Gefahreneinstufungen

Acute Tox. 4 Oral - Ox. Sol. 2 - Resp. Sens. 1 - Skin Sens. 1

Lagerklassenschlüssel

5.1B - Oxidizing hazardous materials

WGK

WGK 1

Flammpunkt (°F)

Not applicable

Flammpunkt (°C)

Not applicable


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.