Direkt zum Inhalt
Merck

W382501

Sigma-Aldrich

Diethylsulfid

98%, FG

Synonym(e):

1,1′-Thiobisethan, Ethylsulfid, NSC 75157

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Lineare Formel:
(C2H5)2S
CAS-Nummer:
Molekulargewicht:
90.19
FEMA-Nummer:
3825
Beilstein:
1696909
EG-Nummer:
MDL-Nummer:
UNSPSC-Code:
12164502
PubChem Substanz-ID:
Flavis-Nummer:
12.113
NACRES:
NA.21

Biologische Quelle

synthetic

Qualität

FG
Halal

Einhaltung gesetzlicher Vorschriften

EU Regulation 1334/2008 & 872/2012
FDA 21 CFR 110

Dampfdruck

105 mmHg ( 37.7 °C)

Assay

98%

Brechungsindex

n20/D 1.442 (lit.)

bp

90-92 °C (lit.)

mp (Schmelzpunkt)

−100 °C (lit.)

Dichte

0.837 g/mL at 25 °C (lit.)

Anwendung(en)

flavors and fragrances

Dokumentation

see Safety & Documentation for available documents

Nahrungsmittelallergen

no known allergens

Organoleptisch

sulfurous

SMILES String

CCSCC

InChI

1S/C4H10S/c1-3-5-4-2/h3-4H2,1-2H3

InChIKey

LJSQFQKUNVCTIA-UHFFFAOYSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Verwandte Kategorien

Piktogramme

FlameExclamation mark

Signalwort

Danger

Gefahreneinstufungen

Eye Irrit. 2 - Flam. Liq. 2 - Skin Irrit. 2

Lagerklassenschlüssel

3 - Flammable liquids

WGK

WGK 3

Flammpunkt (°F)

15.8 °F - closed cup

Flammpunkt (°C)

-9 °C - closed cup

Persönliche Schutzausrüstung

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Kunden haben sich ebenfalls angesehen

R Singh et al.
Chemical research in toxicology, 10(1), 70-77 (1997-01-01)
Postlabeling can be one of the most sensitive methods for the measurement of DNA adducts. However, for the determination of alkylated adducts, essential requirements are standards which must be fully chemically characterized. In order to develop a postlabeling assay for
Beer Singh et al.
Journal of hazardous materials, 139(1), 38-43 (2006-08-26)
Breakthrough behavior of diethyl sulphide vapors on carbon systems such as active carbon, NaOH/CrO3/C, NaOH/CrO3/EDA/C and RuCl3/C has been studied by using modified Wheeler equation and the same was used to calculate the pseudo-first-order rate constant (kv) and kinetic saturation
Taylor C Hayward et al.
Journal of chromatography. A, 1105(1-2), 66-70 (2005-09-30)
A recently reported micro-flame photometric detector (microFPD) has been examined in greater detail for its sulfur response characteristics. While supporting an "upside down" flame on a stainless steel capillary burner (delivering oxygen) in a counter flowing stream of premixed hydrogen
V Vodyanoy et al.
Neuroscience letters, 73(3), 253-258 (1987-01-27)
The steady-state conductance of planar bimolecular lipid membranes (BLMs) modified with rat olfactory epithelial homogenate (ROH) becomes sensitive to very low concentrations of odorant in the presence of adenosine triphosphate (ATP) and guanosine triphosphate (GTP). The chemosensitivity is not observed
Femtochemistry uncovers the nature of electron transfer reactions.
A W Castleman et al.
Proceedings of the National Academy of Sciences of the United States of America, 96(8), 4219-4220 (1999-04-14)

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.