295701

Sigma-Aldrich

Schwefelhexafluorid

≥99.75%

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Lineare Formel:
SF6
CAS-Nummer:
Molekulargewicht:
146.06
EG-Nummer:
MDL-Nummer:
UNSPSC-Code:
51442006
PubChem Substanz-ID:

Dampfdichte

5.11 (vs air)

Qualitätsniveau

Dampfdruck

22 mmHg ( 21.1 °C)

Assay

≥99.75%

bp

−64 °C/1 mmHg (lit.)

mp (Schmelzpunkt)

−50 °C (lit.)

SMILES String

FS(F)(F)(F)(F)F

InChI

1S/F6S/c1-7(2,3,4,5)6

InChIKey

SFZCNBIFKDRMGX-UHFFFAOYSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Allgemeine Beschreibung

Sulfur hexafluoride is a stable gas with higher dielectric strength and density than air. It acts as an insulator in high-voltage circuit breakers as it shows high arc-quenching ability.

Verpackung

Packaged in carbon steel lecture bottles with CGA 110F/180M Al-Si-Bronze needle valve.

Sonstige Hinweise

Rechtliche Hinweise

Aldrich is a registered trademark of Sigma-Aldrich Co. LLC

Empfehlung

Entlüftungsventil

Produkt-Nr.
Beschreibung
Preisangaben

Schlaucholive

Produkt-Nr.
Beschreibung
Preisangaben

auch häufig zusammen mit diesem Produkt gekauft

Produkt-Nr.
Beschreibung
Preisangaben

Piktogramme

Gas cylinder

Signalwort

Warning

H-Sätze

P-Sätze

Gefahreneinstufungen

Press. Gas Liquefied gas

Lagerklassenschlüssel

2A - Gases

WGK

nwg

Flammpunkt (°F)

Not applicable

Flammpunkt (°C)

Not applicable

Persönliche Schutzausrüstung

Eyeshields, Gloves, multi-purpose combination respirator cartridge (US)


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Xinxiao Gao et al.
American journal of ophthalmology, 155(6), 1021-1027 (2013-03-26)
To identify risk factors for development of secondary full-thickness macular holes after pars plana vitrectomy with internal limiting membrane (ILM) peeling for myopic foveoschisis. Retrospective, interventional case series. We retrospectively reviewed the records of 42 eyes (42 patients) treated with
Monica Tj Schütten et al.
JCI insight, 5(6) (2020-02-29)
BACKGROUNDSalt-sensitive hypertension is often accompanied by insulin resistance in obese individuals, but the underlying mechanisms are obscure. Microvascular function is known to affect both salt sensitivity of blood pressure and metabolic insulin sensitivity. We hypothesized that excessive salt intake increases
Sumit P Shah et al.
Retina (Philadelphia, Pa.), 33(2), 356-362 (2013-01-25)
To use spectral domain optical coherence tomography-guided duration of facedown positioning to study anatomical macular hole closure rates. Retrospective review of patients with macular holes undergoing 23-gauge pars plana vitrectomy and intraocular gas tamponade. Spectral domain optical coherence tomography imaging
Christoph Grouls et al.
Radiology, 267(2), 487-495 (2013-01-31)
To investigate the ability of vascular endothelial growth factor receptor type 2 (VEGFR2)-targeted ultrasonographic (US) microbubbles for the assessment of liver dysplasia in transgenic mice. Animal experiments were approved by the governmental review committee. Nuclear factor-κB essential modulator knock-out mice
Dana Gourevich et al.
Ultrasound in medicine & biology, 39(3), 507-514 (2013-01-22)
Ultrasound-mediated targeted drug delivery has been a subject for a dedicated research activity for several decades. Nevertheless, in vitro studies in this field of research are characterized by their inconsistencies. To improve the repeatability of such experiments, a novel approach of

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.