SU860097

Supelco

Flacons Headspace, haut à vis, fond arondi (flacon seul)

volume 20 mL, clear glass vial, thread for 18, O.D. × H 22.5 mm × 75.5 mm, pkg of 100 ea

Synonyme(s) :

Screw cap rounded bottom headspace vial

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
41122001
Nomenclature NACRES :
NB.11

Matériaux

clear glass vial
round bottom

Caractéristiques

closure type screw top vial

Conditionnement

pkg of 100 ea

D.E. × H

22.5 mm × 75.5 mm

Volume

20 mL

Raccords

thread for 18

Compatibilité

for use with CTC PAL (Varian, Gerstel, Atas, Shimadzu)

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

Ces flacons requièrent un bouchon spécial ayant un filetage de 18 mm. Les bouchons filetés standards 18-400 ne s′adapteront pas à ces flacons. Les références de bouchons disponibles pour ces flacons sont les suivantes : SU860101(avec PTFE/silicone, épaisseur 1,3 mm), SU860102 (avec PTFE/butyl, épaisseur 1,6 mm), et SU860103 (avec PTFE/silicone, épaisseur 1,5 mm). Ces bouchons sont faits en acier inoxydable et ils sont magnétiques.

Application

Headspace vial may be used for the following:
  • In the determination of partition coefficient of ethyl acetate in water at 0° C from independent analyses of the total amount of ethyl acetate present in the vial, by automatic equilibrium headspace gas chromatography and vapor phase calibration (VPC).
  • It may be used in the analysis of volatile polar residual solvents present in pharmaceutical products, during development and optimisation of headspace SPME method by GC-MS.
  • It may also be used in the isotopic analysis of 18O in the leaf water of C3 and C4 grasses, during establishing a grassland signature in veins, as it was found that grasses with different photosynthetic pathway have different interveinal differences.
  • It may also find application, in investigating metabolism by Pseudomonas fluorescens of volatile haloaliphatic hydrocarbons like 1,2-dichloroethane and 1,2-dichloropropane, which are some of the major contaminants of underground aquifers.

Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Désolés, nous n'avons pas de COA pour ce produit disponible en ligne pour le moment.

Si vous avez besoin d'assistance, veuillez contacter Service Clients

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

B R Helliker et al.
Proceedings of the National Academy of Sciences of the United States of America, 97(14), 7894-7898 (2000-07-08)
We show that 18O evaporative enrichment of bulk leaf water in grass species can be significantly more enriched than predicted by the Craig-Gordon model, with C4 grasses considerably more enriched than C3 grasses. Our results suggest that the unanticipated 18O
Determination of partition coefficients by automatic equilibrium headspace gas chromatography by vapor phase calibration.
Welter KBC and Bichler C.
Chromatographia, 34 (5-8), 235-240 (1992)
P A Vandenbergh et al.
Applied and environmental microbiology, 54(10), 2578-2579 (1988-10-01)
A Pseudomonas fluorescens strain designated PFL12 was isolated from soil and water that were contaminated with various chloroaliphatic hydrocarbons. The isolate was able to metabolize 1,2-dichloroethane, 1,1,2-trichloroethane, 1,2-dichloropropane, 2,2-dichloropropane, and trichloroethylene.
C C Camarasu
Journal of pharmaceutical and biomedical analysis, 23(1), 197-210 (2000-07-18)
A solid-phase microextraction (SPME) method has been developed and optimized for the polar residual solvent determination in pharmaceutical products. Five different polymer-coated fibers were investigated and the Carboxen/polydimethylsiloxane was found to be the most sensitive for all components. Two Headspace

Protocoles

High performance, reliability, and reproducibility of HS-SPME in combination with GC/MS for the determination of VOCs in water was proven in an interlaboratory trial. The new ISO 17943 using HS-SPME is an improvement on existing official methods for this determination in terms of sensitivity and selectivity.

High performance, reliability, and reproducibility of HS-SPME in combination with GC/MS for the determination of VOCs in water was proven in an interlaboratory trial. The new ISO 17943 using HS-SPME is an improvement on existing official methods for this determination in terms of sensitivity and selectivity.

Les hautes performances, la fiabilité et la reproductibilité de la HS-SPME associée à la GC/MS pour la détermination des COV dans l'eau ont été prouvées dans un essai interlaboratoires. La nouvelle norme ISO 17943, basée sur la HS-SPME, constitue une amélioration des méthodes officielles existantes dédiées à cette détermination en termes de sensibilité et de sélectivité.

Les hautes performances, la fiabilité et la reproductibilité de la HS-SPME associée à la GC/MS pour la détermination des COV dans l'eau ont été prouvées dans un essai interlaboratoires. La nouvelle norme ISO 17943, basée sur la HS-SPME, constitue une amélioration des méthodes officielles existantes dédiées à cette détermination en termes de sensibilité et de sélectivité.

Afficher tout

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique