WHA13549204
Whatman® FF170HP Din A
sheets nitrocellulose membrane, pack of 10 sheets
Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme
About This Item
Produits recommandés
Matériaux
polyester backing
sheets nitrocellulose membrane
Stérilité
non-sterile
Conditionnement
pack of 10 sheets
Fabricant/nom de marque
Whatman 13549204
Taille
210 m × 297 mm
Épaisseur
200 μm
Description générale
FF High Performance (HP) membranes are part of the AE family, which are directly cast onto a plastic film. The FFHP membranes are a result of improved membrane casting procedures, which result in enhanced intra- and inter lot consistency and sharper lines. The surface is uniform without unincorporated nitrocellulose powder and the fine structure fiber distribution provides large internal surfaces for binding proteins
Nitrocellulose membranes are a key functional part of lateral-flow assays. The membrane must provide sufficient protein binding to enable the formation of a sharp and intense capture line, but at the same time the level of nonspecific background must be low for easy interpretation of results. Nitrocellulose membranes are available in a range of wicking rates and formulations. It has long been known that the wicking rate of a membrane has a significant impact on test sensitivity.
Nitrocellulose membranes are a key functional part of lateral-flow assays. The membrane must provide sufficient protein binding to enable the formation of a sharp and intense capture line, but at the same time the level of nonspecific background must be low for easy interpretation of results. Nitrocellulose membranes are available in a range of wicking rates and formulations. It has long been known that the wicking rate of a membrane has a significant impact on test sensitivity.
Caractéristiques et avantages
A backed and highly consistent membrane for use with low viscosity samples in a lateral flow assay.
- Exceptional intra- and inter-lot consistency as demonstrated by a coefficient of variation (CV) for capillary rise of < 10%.</LI>Improved assay consistency and reproducible limit of detection.
- Reduced assay optimization costs, compared to a less consistent membrane.
Informations légales
Whatman is a registered trademark of Cytiva
Mention d'avertissement
Warning
Mentions de danger
Conseils de prudence
Code de la classe de stockage
11 - Combustible Solids
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Les clients ont également consulté
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique