Accéder au contenu
MilliporeSigma

LC-ESI-MS determination and pharmacokinetics of adrafinil in rats.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2008-08-30)
R Nageswara Rao, Dhananjay D Shinde, M V N Kumar Talluri, Sachin B Agawane
RÉSUMÉ

A highly sensitive and specific liquid chromatography/tandem mass spectrometric (LC-MS/MS) method for investigating the pharmacokinetics of adrafinil in rats was developed. Rat serum pretreated by solid-phase extraction (SPE) was analyzed by LC-MS/MS with an electrospray ionization (ESI) interface. The mobile phase consisted of acetonitrile:water:acetic acid (35:65:0.1, v/v/v) in an isocratic elution mode pumped at 1.0 ml/min. The analytical column (250 mm x 4.6 mm i.d.) was packed with Kromasil C(18) material (5.0 microm). The standard curve was linear from 16.5 to 5000 ng/ml. The assay was specific, accurate (R.S.D.<2.6%), precise and reproducible (within- and between-day precisions R.S.D. <7.0% and <9.0%, respectively). Adrafinil in rat serum was stable over three freeze-thaw cycles at ambient temperature for 6 h. The method had a lower limit of quantitation of 16.5 ng/ml, which offered high sensitivity for the determination of adrafinil in serum. The method was successfully applied to pharmacokinetic studies of adrafinil after an oral administration to rats.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Supelco
Colonne HPLC Discovery® C18, 5 μm particle size, L × I.D. 25 cm × 4.6 mm
Supelco
Colonne HPLC Discovery® C18, 5 μm particle size, L × I.D. 15 cm × 4.6 mm
Supelco
Colonne HPLC Discovery® C18, 5 μm particle size, L × I.D. 10 cm × 4.6 mm
Supelco
Précolonne Discovery® C18 Supelguard, Kit, 5 μm particle size, L × I.D. 2 cm × 4 mm
Supelco
Colonne HPLC Discovery® C18, 5 μm particle size, L × I.D. 5 cm × 4.6 mm
Supelco
Colonne HPLC Discovery® C18, 5 μm particle size, L × I.D. 15 cm × 3 mm
Supelco
Colonne HPLC Discovery® C18, 5 μm particle size, L × I.D. 25 cm × 4 mm
Supelco
Colonne HPLC Discovery® C18, 5 μm particle size, L × I.D. 15 cm × 4 mm
Supelco
Précolonne Discovery® C18 Supelguard, 5 μm particle size, L × I.D. 2 cm × 4 mm, pkg of 2 ea
Supelco
Colonne HPLC Discovery® C18, 5 μm particle size, L × I.D. 12.5 cm × 4 mm
Supelco
Colonne HPLC Discovery® C18, 5 μm particle size, L × I.D. 25 cm × 21.2 mm
Supelco
Colonne HPLC Discovery® C18, 5 μm particle size, L × I.D. 12.5 cm × 4.6 mm
Supelco
Colonne HPLC Discovery® C18, 5 μm particle size, L × I.D. 10 cm × 2.1 mm
Supelco
Colonne HPLC Discovery® C18, 5 μm particle size, L × I.D. 10 cm × 4 mm
Supelco
Colonne HPLC Discovery® C18, 5 μm particle size, L × I.D. 5 cm × 2.1 mm
Supelco
Précolonne Discovery® C18 Supelguard, Kit, 5 μm particle size, L × I.D. 2 cm × 2.1 mm
Supelco
Colonne HPLC Discovery® C18, 5 μm particle size, L × I.D. 25 cm × 3 mm
Supelco
Colonne HPLC Discovery® C18, 5 μm particle size, L × I.D. 15 cm × 2.1 mm
Supelco
Colonne HPLC Discovery® C18, 5 μm particle size, L × I.D. 25 cm × 10 mm
Supelco
Colonne HPLC Discovery® C18, 5 μm particle size, L × I.D. 12.5 cm × 2.1 mm
Supelco
Précolonne Discovery® C18 Supelguard, 5 μm particle size, L × I.D. 2 cm × 2.1 mm, pkg of 2 ea
Supelco
Précolonne Discovery® C18 Supelguard, Kit, 5 μm particle size, L × I.D. 2 cm × 3 mm
Supelco
Précolonne Discovery® C18 Supelguard, 5 μm particle size, L × I.D. 2 cm × 3 mm, pkg of 2 ea