Pular para o conteúdo
Merck
Todas as fotos(1)

Documentos Principais

RAD121

radiello Triangular Support Plate

pk of 20

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Código UNSPSC:
41104008
NACRES:
NB.24
Preço e disponibilidade não estão disponíveis no momento.

embalagem

pk of 20

fabricante/nome comercial

Radiello Code 121

técnica(s)

passive air sampling: suitable

aplicação(ões)

air monitoring
environmental
industrial hygiene

Descrição geral

A radiello diffusive sampler consists of 3 parts: the diffusive body, the adsorbent tube, and the triangular support plate. For personal air sampling, a vertical adapter can be installed. The adsorbent cartridge is removed from its glass or plastic storage tube and is inserted into the diffusive body. This is then threaded onto the triangular support plate in order to place the sampler in its sampling position.
The triangular support plate acts as both a closure and means of suspension for the Radiello diffusive body and cartridge adsorbent during passive air sampling. Each support plate is threaded for easy diffusive body attachment. Each plate includes a clip and transparent adhesive pocket to hold the Radiello barcode label.

Informações legais

radiello is a trademark of Institi Clinici Scientifici Maugeri

Escolha uma das versões mais recentes:

Certificados de análise (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documentos section.

Se precisar de ajuda, entre em contato Atendimento ao cliente

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Isabel M Morales Terrés et al.
Journal of environmental management, 91(12), 2754-2762 (2010-09-03)
This paper describes a novel methodology for evaluating the extent to which petrol stations affect their surroundings. The method is based on the fact that the ratio of the concentrations of aliphatic and aromatic hydrocarbon pollutants in the air of
Study of the dispersion of VOCs emitted by a municipal solid waste landfill
Chiriac, R., et al.
Atmospheric Environment, 43 (11), 1926-1931 (2009)
Benoît Oury et al.
Journal of occupational and environmental hygiene, 3(10), 547-557 (2006-08-16)
Diffusive sampling is particularly suited to determine time-weighted average volatile organic compound (VOC) concentration in occupational hygiene and environmental air monitoring. The purpose of this study was to measure the sampling rate variation of four different samplers in a special
Armelle Vallat et al.
Phytochemistry, 66(13), 1540-1550 (2005-06-14)
Headspace volatiles from apple-bearing twigs were collected in the field with a Radiello sampler during three different diurnal periods over the complete fruit growing season. Analyses by thermal desorption-GC-MS identified a total of 62 compounds in changing quantities, including the
P Bruno et al.
Waste management (New York, N.Y.), 27(4), 539-544 (2006-05-23)
Nuisance caused by odors is one of the most important problems for waste management plants. To control an odor nuisance, it must first be quantified. The analytical difficulties in odor measurements are related to the high number of volatile components

Artigos

radiello® Diffusive Air Sampling Application - Ammonia

radiello® Diffusive Air Sampling Application - Hydrogen Sulfide

Learn about radiello® Diffusive Sampling Aldehydes Applications & Methods.

Learn the how the diffusive air sampler works to see if it’s the right fit for you.

Protocolos

Protocol for radiello® Diffusive Air Sampling Application - Nitrogen and Sulfur Dioxide

Volatile organic compounds are trapped by adsorption and recovered by thermal desorption, analysis is performed by capillary gas chromatography and FID or MS detection.

The adsorbing cartridge is formed by a micropore polyethylene tube filled with silica gel coated with 4,4’-dipyridylethylene and closed, at one end, by a PTFE cap. Upon exposure, acid-catalysed ozonolysis of 4,4’-dipyridylethylene leads to 4-pyridylaldehyde.

Protocol for radiello® Diffusive Air Sampling Application - Anaesthetic Gases and Vapors

Ver tudo

Questions

  1. what type of Radiello sampler can be used for ENVIRONMENTAL monitoring of Benzene toluene and xylene (BTX) in petrol stations? Where is the best location to place the sampler to assess BTX in ambient air in petrol station

    1 answer
    1. Two ready-to-use starter kits are available for environmental VOC/BTEX sampling. For chemical desorption techniques, the sampler kit is available under Product No. RAD130S. This kit includes 2 RAD130 adsorbing cartridges and barcode labels, 1 RAD120 white diffusive body, 1 RAD121 triangular support plate, and an instruction sheet. Each of the kit components is available separately.

      For thermal desorption techniques, the sampler kit is available under Product No. RAD145S. This kit includes 2 RAD145 adsorbing cartridges and barcode labels, 1 RAD1202 yellow diffusive body, 1 RAD121 triangular support plate, and an instruction sheet. Similarly, each of the kit components is available separately.

      For outdoor sampling, an outdoor shelter is available under Product No. RAD196. This shelter is designed to house and protect the sampler(s) from the elements. The outdoor shelter can be mounted on any vertical pole near the sampling site, including lamp posts, traffic lights, and telephone poles of various diameters. Spare mounting strips are available under Product No. RAD198.

      Helpful?

Reviews

No rating value

Active Filters

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica