G005822
GC Analysis of FAMEs in Peanuts on Omegawax
suitable for GC
About This Item
técnica(s)
gas chromatography (GC): suitable
parâmetros de teste
column: OMEGAWAX 250, 30 m x 0.25 mm I.D., 0.25 μm (24136)
oven: 170 °C, 1 °C/min to 225 °C
inj. temp.: 250 °C
detector: FID, 250 °C
carrier gas: helium, 1.2 mL/min constant flow
injection: 1 μL, split 100:1
liner: 4 mm ID FocusLiner w/taper
sample: Dry roasted, unsalted peanuts prepared for analysis per AOCS Official Method Ce 1k-09
aplicação(ões)
agriculture
food and beverages
Nota de análise
The samples were prepared using acid digestion /alkali hydrolysis followed by methylation as described in AOCS Official Method Ce 1k-09. BHT was added as an antioxidant prior to extraction. All samples were concentrated to 1 mL prior to GC analysis. The Omegawax GC column was used in the analysis of the saturated and unsaturated fatty acids present in the sample.