25312
SPB®-608 Capillary GC Column
L × I.D. 30 m × 0.53 mm, df 0.50
Sinônimo(s):
SPB-608, 30M .50UM.53MM
Faça loginpara ver os preços organizacionais e de contrato
About This Item
Produtos recomendados
Materiais
fused silica
Agency
ASTM® D4861
EPA TO-10,IP-8,608.1/608.2,608/8081/OLM04.2 PEST,610,8100,8141,8082
Parâmetros
≤25-300 °C temperature (isothermal or programmed)
Valor beta
265
df
0.50
técnica(s)
gas chromatography (GC): suitable
C × D.I.
30 m × 0.53 mm
aplicação(ões)
agriculture
environmental
food and beverages
tipo de coluna
capillary intermediate polar
Procurando produtos similares? Visita Guia de comparação de produtos
Categorias relacionadas
Descrição geral
Capillary GC column is also known as open tubular column. The carrier gas flows through the central aperture and is unrestricted throughout the length of the column.
Application: This column is specially tested with low concentrations of 18 chlorinated pesticides, using an ECD detector. In addition to selectivity and efficiency, it is also tested to ensure minimum breakdown of 4,4′-DDT and endrin. This column is also suitable for use in herbicide analyses.
USP Code: None
Phase:
USP Code: None
Phase:
- Bonded
- Proprietary
- Subambient to 300 °C (isothermal or programmed)
Aplicação
SPB-608 Capillary Column was used in gas chromatography with electron capture detector (GC-ECD), which was used for the determination of methylmercury in sediment after alkaline digestion.
Outras notas
We offer a variety of chromatography accessories including analytical syringes
Informações legais
ASTM is a registered trademark of American Society for Testing and Materials
SPB is a registered trademark of Merck KGaA, Darmstadt, Germany
Choose from one of the most recent versions:
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
GC-ECD determination of methylmercury in sediment samples using a SPB-608 capillary column after alkaline digestion.
Microchemical Journal, Devoted to the Application of Microtechniques in All Branches of Science, 55 (1), 44-45 (1997)
Sichuan da xue xue bao. Yi xue ban = Journal of Sichuan University. Medical science edition, 37(3), 480-483 (2006-06-10)
To develop a capillary gas chromatographic method for the determination of mannitol in health food. Mannitol was extracted from the sample with water by ultrasonic wave. The aliquot of sample solution was acetylated to form mannitol hexacetate with lower boiling
Introduction to Analytical Gas Chromatography, 101-102 (1997)
Chromatograms
suitable for GC, application for air monitoringNossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica