Pular para o conteúdo
Merck
Todas as fotos(1)

Documentos Principais

P8824

Sigma-Aldrich

Polyanetholesulfonic acid sodium salt

BioUltra

Sinônimo(s):

Sodium polyanetholesulfonate

Faça loginpara ver os preços organizacionais e de contrato

Selecione um tamanho

5 G
R$ 928,00
25 G
R$ 3.510,00

R$ 928,00


Previsão de entrega em28 de maio de 2025


Solicite uma grande encomenda

Selecione um tamanho

Alterar visualização
5 G
R$ 928,00
25 G
R$ 3.510,00

About This Item

Número CAS:
Número MDL:
Código UNSPSC:
12162002
NACRES:
NA.77

R$ 928,00


Previsão de entrega em28 de maio de 2025


Solicite uma grande encomenda

linha de produto

BioUltra

Formulário

powder

Impurezas

≤0.001% Phosphorus (P)
≤0.1% Insoluble matter

traços de ânion

chloride (Cl-): ≤0.1%

traços de cátion

Al: ≤0.0005%
Ca: ≤0.05%
Cu: ≤0.0005%
Fe: ≤0.001%
K: ≤0.5%
Mg: ≤0.01%
NH4+: ≤0.05%
Pb: ≤0.001%
Zn: ≤0.0005%

cadeia de caracteres SMILES

C/C=C/C1=CC=C(C=C1)OC.[O-]S(=O)[O-].[Na+]

InChI

1S/C10H12O.Na.H2O3S/c1-3-4-9-5-7-10(11-2)8-6-9;;1-4(2)3/h3-8H,1-2H3;;(H2,1,2,3)/q;+1;/p-2/b4-3+;;

chave InChI

JKJBFNAERWARKW-CZEFNJPISA-L

Procurando produtos similares? Visita Guia de comparação de produtos

Descrição geral

Canonical SMILES: CC=CC1=CC=C(C=C1)OC.[O-]S(=O)[O-].[Na+]

Pictogramas

Exclamation mark

Palavra indicadora

Warning

Frases de perigo

Classificações de perigo

Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3

Órgãos-alvo

Respiratory system

Código de classe de armazenamento

11 - Combustible Solids

Classe de risco de água (WGK)

WGK 3

Ponto de fulgor (°F)

Not applicable

Ponto de fulgor (°C)

Not applicable

Equipamento de proteção individual

dust mask type N95 (US), Eyeshields, Gloves


Escolha uma das versões mais recentes:

Certificados de análise (COA)

Lot/Batch Number

Não está vendo a versão correta?

Se precisar de uma versão específica, você pode procurar um certificado específico pelo número do lote ou da remessa.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

B L Wasilauskas et al.
Journal of clinical microbiology, 35(3), 588-590 (1997-03-01)
We previously reported an inhibitory effect on Mycobacterium avium-M. intracellulare (MAI) when blood collected and processed with the Isolator system was placed in BACTEC 12B bottles for radiometric monitoring. We sought to identify the specific component(s) of the Isolator lysis-anticoagulant
E R Schnur et al.
Journal of clinical microbiology, 27(4), 654-656 (1989-04-01)
During an 8-month period at Children's Hospital, Oakland, Calif., a 9% rate for positive blood culture for children with Neisseria meningitidis meningitis was identified. The blood culture system used in each case was the BACTEC NR 730. This rate seemed
Kerry Varettas et al.
Journal of clinical microbiology, 43(9), 4613-4615 (2005-09-08)
The tube coagulase test (TCT) performed directly from positive blood culture bottles has been used to reduce the turnaround time for identifying Staphylococcus aureus. Most reports have shown the test to be specific but often lacking sufficient sensitivity to be
J Cerda et al.
British journal of experimental pathology, 67(5), 623-628 (1986-10-01)
Levels of plasma fibronectin (Fn) were 63% lower than normal 15 min after the intravenous injection of liquoid (P less than 0.01); 3 h later they were still low but rebounded to 35% above normal (P less than 0.01) by
C Gamazo et al.
Journal of clinical microbiology, 31(12), 3200-3203 (1993-12-01)
The detection of Brucella bacteremia by subculture does not always correlate with a positive signal in the BACTEC NR730 nonradiometric system (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.). The effect of the inoculum size, pH, sodium polyanetholesulfonate, carbon sources (i-erythritol

Questions

Reviews

No rating value

Active Filters

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica