Pular para o conteúdo
Merck
Todas as fotos(1)

Documentos Principais

81223

Supelco

Polyethylene

analytical standard, for GPC, 2,000

Faça loginpara ver os preços organizacionais e de contrato

Selecione um tamanho

100 MG
R$ 1.954,00

R$ 1.954,00


Check Cart for Availability

Solicite uma grande encomenda

Selecione um tamanho

Alterar visualização
100 MG
R$ 1.954,00

About This Item

Fórmula linear:
H(CH2CH2)nH
Número CAS:
Número MDL:
Código UNSPSC:
41116107
ID de substância PubChem:
NACRES:
NA.24

R$ 1.954,00


Check Cart for Availability

Solicite uma grande encomenda

grau

analytical standard
for GPC

Nível de qualidade

prazo de validade

limited shelf life, expiry date on the label

peso molecular

Mn ~1790
Mp ~2030
Mw ~2010

técnica(s)

gel permeation chromatography (GPC): suitable

Mw/Mn

~1.12

Formato

neat

cadeia de caracteres SMILES

C=C

InChI

1S/C2H4/c1-2/h1-2H2

chave InChI

VGGSQFUCUMXWEO-UHFFFAOYSA-N

Procurando produtos similares? Visita Guia de comparação de produtos

Código de classe de armazenamento

11 - Combustible Solids

Classe de risco de água (WGK)

WGK 3

Ponto de fulgor (°F)

Not applicable

Ponto de fulgor (°C)

Not applicable

Equipamento de proteção individual

Eyeshields, Gloves, type N95 (US)


Escolha uma das versões mais recentes:

Certificados de análise (COA)

Lot/Batch Number

Não está vendo a versão correta?

Se precisar de uma versão específica, você pode procurar um certificado específico pelo número do lote ou da remessa.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Os clientes também visualizaram

Slide 1 of 1

1 of 1

Polypropylene (PP) ERM®, certified reference material

ERMEC591

Polypropylene (PP)

Lisa K McCarthy et al.
Pediatrics, 132(1), e135-e141 (2013-06-19)
Hypothermia on admission to the NICU is associated with increased mortality in preterm infants. Many newborns are hypothermic on admission despite using polyethylene bags (PBs). Using exothermic mattresses (EMs) in addition to PBs may reduce hypothermia but increase hyperthermia. We
Mahtab Memarpour et al.
The journal of adhesive dentistry, 15(1), 85-91 (2013-03-28)
To evaluate the clinical performance of polyethylene fiber for anterior primary teeth restorations in children after 2.5 years, according to modified Ryge criteria. Fifty-five maxillary incisors with extensive caries in 24 Iranian patients (mean age 4.2 years) were restored. All
[Technologies for manufacturing ultra-high molecular polyethylene-based porous structures for bone implants].
A V Maksimkin et al.
Meditsinskaia tekhnika, (2)(2), 16-20 (2013-06-26)
Agnieszka Karbownik et al.
Acta poloniae pharmaceutica, 70(2), 301-307 (2013-04-26)
The study concerned the stability of calcium folinate in concentrate in glass vials and diluted in polyethylene (PE) bags stored at 15-25 degrees C and 2-8 degrees C for up to 34 days. Original vials of calcium folinate injection (10
Ryan M Baxter et al.
Journal of biomedical materials research. Part B, Applied biomaterials, 101(3), 467-475 (2013-02-26)
Despite the widespread implementation of highly cross-linked polyethylene (HXLPE) liners to reduce the clinical incidence of osteolysis, it is not known if the improved wear resistance will outweigh the inflammatory potential of HXLPE wear debris generated in vivo. Thus, we

Questions

1–2 of 2 Questions  
  1. Is your polyethylene analytical standard for GPC, with a molecular weight of 2,000, soluble for use in biological studies such as cell assays? If so, could you please provide information on its solubility properties and recommended solvents?"

    1 answer
    1. This product is not water soluble, and it is not intended for use in biological studies. It is slightly soluble in organic solvents such as toluene, xylene and cyclohexane, but none of those are water-miscible. Perhaps the Polyethylene could be used as an aqueous suspension (prepared by sonication), and not as a true solution.

      Helpful?

  2. Sehr geehrtes Team, ich bin auf der Suche nach einem PE welcher als Standard für die Schmelztemperaturbestimmung genutzt werden kann. Ist die Schmelztemperatur dieses PE Standards zertifiziert? Falls nicht, haben sie ein anderes Polymer für diesen Zweck?

    1 answer
    1. The melting temperature of this PE is not determined. The suitability for use as a melting point standard has not been validated.

      Helpful?

Reviews

No rating value

Active Filters

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica