Pular para o conteúdo
Merck
Todas as fotos(1)

Documentos

34114

Supelco

BDE No 85 solution

50 μg/mL in isooctane, analytical standard

Sinônimo(s):

2,2′,3,4′,4-Pentabromodiphenyl ether solution, 2,2′,3,4′,4-PentaBDE, PBDE 85

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Fórmula empírica (Notação de Hill):
C12H5Br5O
Número CAS:
Peso molecular:
564.69
Número CE:
Número MDL:
Código UNSPSC:
41116107
ID de substância PubChem:
NACRES:
NA.24

grau

analytical standard

prazo de validade

limited shelf life, expiry date on the label

concentração

50 μg/mL in isooctane

técnica(s)

HPLC: suitable
gas chromatography (GC): suitable

aplicação(ões)

environmental

formato

single component solution

temperatura de armazenamento

2-8°C

cadeia de caracteres SMILES

Brc1ccc(Oc2ccc(Br)c(Br)c2Br)c(Br)c1

InChI

1S/C12H5Br5O/c13-6-1-3-9(8(15)5-6)18-10-4-2-7(14)11(16)12(10)17/h1-5H

chave InChI

DMLQSUZPTTUUDP-UHFFFAOYSA-N

Descrição geral

BDE No 85 is an pollutant with low acute toxicity, released into the environment from various sources and belonging to the class of polybrominated diphenyl ethers. It can find wide applications as additive flame-retardants in consumer products ranging from textiles to polymers.

Aplicação

BDE No 85 may be used as an analytical reference standard for analysis of the analyte in environmental samples such as river sediments using gas chromatography coupled to mass spectrometry (GC-MS) and selective pressurized liquid extraction followed by gas chromatography coupled to negative ion chemical ionization-mass spectrometry (GC-NCI-MS).
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.

Outras notas

The customer needs to make sure that the standard is homogeneous, this can be achieved by shaking, vortexing , or sonicating the ampoule before opening the ampoule. Care should be taken when opening the ampoule to avoid any injuries from the broken glass.
The standard should be transferred to a clean and appropriate vial or flask using clean pipettes or micro pipettes. The vial should be immediately capped to avoid any loss or evaporation of the solvent.
After opening the ampoule, the standard should not be stored or kept in the ampoule. To preserve the integrity of the product, the standard should be transferred to an appropriate vial that must be capped and stored according to the recommendation on the Certificate of Analysis.

Palavra indicadora

Danger

Frases de perigo

Classificações de perigo

Aquatic Acute 1 - Aquatic Chronic 1 - Asp. Tox. 1 - Flam. Liq. 2 - Skin Irrit. 2 - STOT SE 3

Órgãos-alvo

Central nervous system

Código de classe de armazenamento

3 - Flammable liquids

Classe de risco de água (WGK)

WGK 2

Ponto de fulgor (°F)

10.4 °F - closed cup

Ponto de fulgor (°C)

-12 °C - closed cup

Equipamento de proteção individual

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


Choose from one of the most recent versions:

Certificados de análise (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Determination of decabromodiphenyl ether in sediments using selective pressurized liquid extraction followed by GC-NCI-MS.
Eljarrat E, et al.
Analytical and Bioanalytical Chemistry, 378(3), 610-614 (2004)
GC / MS analysis of polybrominated diphenyl ethers in fish collected from the Inland Sea of ??Seto, Japan.
Akutsu K, et al.
Chemosphere, 44(6), 1325-1333 (2001)

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica