Pular para o conteúdo
Merck
Todas as fotos(2)

Documentos Principais

EHIFIPN-RO

Roche

Expand High FidelityPLUS PCR System, dNTPack

sufficient for ≤125 reactions (04743725001), sufficient for ≤500 reactions (04743733001), suitable for PCR, dNTPs included

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Número da licença da enzima:
Código UNSPSC:
41106300
NACRES:
NA.21

grau

Molecular Biology

Nível de qualidade

Formulário

liquid

uso

sufficient for ≤125 reactions (04743725001)
sufficient for ≤500 reactions (04743733001)

Características

High Fidelity PCR
dNTPs included
hotstart: no

embalagem

pkg of 125 U (04743725001)
pkg of 500 U (04743733001 [2x250 U])

fabricante/nome comercial

Roche

concentração

50 U/mL (working concentration)

Parâmetros

72 °C optimum reaction temp.

técnica(s)

PCR: suitable

Impurezas

ribonucleases, none detected
≤50 cfu/mL bioburden

cor

colorless

entrada

purified DNA

solubilidade

water: miscible

temperatura de armazenamento

−20°C

Descrição geral

The Expand High FidelityPLUS PCR System is a blend of Taq DNA Polymerase and a thermostable proofreading protein that lacks polymerase activity.
This enzyme blend is designed to amplify fragments up to 5 kb from all types of DNA with high yield and fidelity.
In addition, this enzyme blend also incorporates dUTP and, in combination with Uracil-DNA Glycosylase, can be used to safeguard PCR reactions from cross contamination.
The fidelity of DNA synthesis with the Expand High FidelityPLUS PCR System shows a 2-fold increase compared to the fidelity obtained with the Expand High Fidelity PCR System and a 6-fold increase compared to the fidelity obtained with Taq DNA Polymerase.
These characteristics make the Expand High FidelityPLUS PCR System blend the product of choice if a larger number of targets need to be amplified at the same time with high yield in combination with improved accuracy. In addition, the product can be used for the efficient labeling of DNA fragments with radioactive or non-radioactive modified nucleotides.

Aplicação

  • The Expand High FidelityPLUS PCR System is designed for the robust amplification of fragments up to 5 kb from all types of DNA with outstanding yield, specificity, sensitivity, and accuracy. This convenient dNTPack is the product of choice for the development of a new amplification assay or the optimization of an existing assay. PCR
  • RT-PCR
  • Primer extension
  • Carryover prevention
It has been used in the ultradeep pyrosequencing methods, inverse PCR and to measure the repeat length of CGG sequences.
Twofold higher yield and threefold greater fidelity are obtained compared to Taq DNA Polymerase. Use Expand High FidelityPLUS PCR System for:
  • PCR up to 5kb
  • RT-PCR up to 5kb

Características e benefícios

Expand High FidelityPLUS PCR System is a mixture of Taq DNA polymerase and a DNA polymerase with proofreading activity. The Expand High FidelityPLUS PCR System shows a twofold increase in fidelity compared to the Expand High Fidelity PCR System, and a sixfold increase compared to Taq DNA Polymerase.
By incorporating dUTP, Uracil-DNA Glycosylase can be used to prevent PCR product carryover. Use this kit for efficient labeling of DNA with radioactive or non-radioactive nucleotides. It is optimized for PCR of DNA fragments up to 5kb.
Use 2.5U for a standard 50μl PCR.

  • Safeguard against cross-contamination.
This is the choice for large numbers of amplifications.
  • Obtain sixfold higher fidelity and higher yields,
compared to Taq DNA Polymerase.
  • Efficiently label DNA.
Use this kit to label DNA with radioactive or nonradioactive nucleotides.
  • Cost-effective.
Use the convenient solution of premixed PCR grade dNTPs.

Embalagem

1 kit containing 5 components

Qualidade

Each lot is PCR function-tested using human genomic DNA and EPO primers specific for a 1.8kb PCR product, and tPA primers specific for a 4.8kb PCR product.

Definição da unidade

Volume Activity: 5 U/μl

Outras notas

For life science research only. Not for use in diagnostic procedures.

Informações legais

Use of this product is covered by US patent claims and corresponding patent claims outside the US. The purchase of this product includes a limited, non-transferable immunity from suit under the foregoing patent claims for using only this amount of product for the purchaser′s own internal research. No right under any other patent claim, no right to perform any patented method, and no right to perform commercial services of any kind, including without limitation reporting the results of purchaser′s activities for a fee or other commercial consideration, is conveyed expressly, by implication, or by estoppel. This product is for research use only. Diagnostic uses under Roche patent claims require a separate license from Roche. Further information on purchasing licenses may be obtained by contacting the Director of Licensing, Applied Biosystems, 850 Lincoln Centre Drive, Foster City, California 94404, USA.
Expand is a trademark of Roche

Somente componentes do kit

Nº do produto
Descrição

  • Expand High FidelityPLUS Enzyme Blend 5 U/μl

  • Expand High FidelityPLUS Reaction Buffer, with 7.5 mM MgCl2 5x concentrated

  • Expand High FidelityPLUS Reaction Buffer, without MgCl2 5x concentrated

  • MgCl2 Stock Solution 25 mM

  • PCR Nucleotide Mix

Frases de perigo

Declarações de precaução

Classificações de perigo

Aquatic Chronic 3

Código de classe de armazenamento

12 - Non Combustible Liquids

Classe de risco de água (WGK)

WGK 2

Ponto de fulgor (°F)

does not flash

Ponto de fulgor (°C)

does not flash


Escolha uma das versões mais recentes:

Certificados de análise (COA)

Lot/Batch Number

Não está vendo a versão correta?

Se precisar de uma versão específica, você pode procurar um certificado específico pelo número do lote ou da remessa.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Os clientes também visualizaram

Slide 1 of 2

1 of 2

Vici Varghese et al.
PloS one, 5(6), e10992-e10992 (2010-06-12)
The HIV-1 nucleoside RT inhibitor (NRTI)-resistance mutation, K65R confers intermediate to high-level resistance to the NRTIs abacavir, didanosine, emtricitabine, lamivudine, and tenofovir; and low-level resistance to stavudine. Several lines of evidence suggest that K65R is more common in HIV-1 subtype
Ken Kwok-Keung Chan et al.
Stem cells and development, 17(4), 825-836 (2008-09-16)
The utilization of human embryonic stem cells (hESC) in regenerative medicine largely depends on the development of technologies that will allow efficient genetic manipulation of the cells in vitro. Although a few studies have described the transfection of hESC for
J R Brouwer et al.
Experimental cell research, 313(2), 244-253 (2006-12-08)
The human FMR1 gene contains a CGG repeat in its 5' untranslated region. The repeat length in the normal population is polymorphic (5-55 CGG repeats). Lengths beyond 200 CGGs (full mutation) result in the absence of the FMR1 gene product

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica