Pular para o conteúdo
Merck
Todas as fotos(2)

Documentos Principais

MAGPMAG-24K

Millipore

MILLIPLEX® Mouse Angiogenesis/Growth Factor Magnetic Bead Panel - Cancer Multiplex Assay

for the simultaneous quantification of multiple analytes

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Código UNSPSC:
12161503
eCl@ss:
32161000
NACRES:
NA.84

To order a Milliplex® kit, please search for your analyte of interest.

Nível de qualidade

reatividade de espécies

mouse

fabricante/nome comercial

Milliplex®

assay range

accuracy: 90-104%
standard curve range: 1-1,000 pg/mL
(Endothelin-1)

standard curve range: 137-100,000 pg/mL
(Follistatin)

standard curve range: 137-100,000 pg/mL
(HGF)

standard curve range: 137-100,000 pg/mL
(SDF-1)

standard curve range: 14-10,000 pg/mL
(IL-1b)

standard curve range: 14-10,000 pg/mL
(Leptin)

standard curve range: 14-10,000 pg/mL
(MIP-1α)

standard curve range: 14-10,000 pg/mL
(sALK-1)

standard curve range: 14-10,000 pg/mL
(sCD31/ PECAM-1)

standard curve range: 27-20,000 pg/mL
(Angiopoietin-2)

standard curve range: 27-20,000 pg/mL
(EGF)

standard curve range: 27-20,000 pg/mL
(Endoglin)

standard curve range: 27-20,000 pg/mL
(MCP-1)

standard curve range: 27-20,000 pg/mL
(VEGF-C)

standard curve range: 3-2,000 pg/mL
(PLGF-2)

standard curve range: 6-4,000 pg/mL
(TNFα)

standard curve range: 6-4,000 pg/mL
(VEGF-A)

standard curve range: 69-50,000 pg/mL
(FGF-2/FGF-basic)

standard curve range: 69-50,000 pg/mL
(Prolactin)

standard curve range: 69-50,000 pg/mL
(VEGF-D)

standard curve range: 69-50,000 pg/mL
(sFasL)

standard curve range: 7-5,000 pg/mL
(Amphiregulin)

standard curve range: 7-5,000 pg/mL
(Betacellulin)

standard curve range: 7-5,000 pg/mL
(G-CSF)

standard curve range: 7-5,000 pg/mL
(IL-17A)

standard curve range: 7-5,000 pg/mL
(IL-6)

standard curve range: 7-5,000 pg/mL
(KC/CXCL1)

técnica(s)

multiplexing: suitable

método de detecção

fluorometric (Luminex xMAP)

Condições de expedição

wet ice

Descrição geral

Angiogenesis, the development of new vascular networks, is a key process in normal growth and development as well as in wound healing, with homeostasis maintained by a delicate balance of angiogenic factors and inhibitors. Consequently, insufficient, or excessive blood vessel growth underlies many diseases, including cardiovascular disease, diabetic ulcers, macular degeneration, and cancer. Angiogenesis plays a significant role in tumor growth and metastasis.

MILLIPLEX® Mouse Angiogenesis//Growth Factor Panel, is a 24-plex (for serum/plasma) or 27-plex (for cell culture) kit to be used for the simultaneous quantification of the following analytes: Angiopoietin-2, G-CSF, sFasL, sAlk-1, Amphiregulin, Leptin, IL-1b, Betacellulin, EGF, IL-6, Endoglin, Endothelin-1, FGF-2, Follistatin, HGF, PECAM-1, IL-17, PLGF-2, KC, MCP-1, Prolactin, MIP-1a, SDF-1, VEGF-C, VEGF-D, VEGF-A, and TNFα. This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.

The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.

Panel Type: Circulating Cancer

Especificidade

Cross-reactivity between the antibodies and any of the other analytes in this panel is non-detectable or negligible.

Aplicação

  • Analytes: sALK-1, Amphiregulin, Angiopoietin-2, Betacellulin, sCD31/sPECAM-1, EGF, Endoglin, Endothelin-1, sFasL, FGF-2 (FGF-basic), Follistatin (FST), G-CSF, HGF, IL-1β, IL-6, IL-17A (CTLA8), KC (GRO/CINC-1/CXCL1), Leptin, MCP-1 (CCL2), MIP-1α (CCL3), Placental Growth Factor 2 (PLGF-2), Prolactin, SDF-1 (CXCL12), TNF-α, VEGF-A, VEGF-C, VEGF-D
  • NOTE: Angiopoeitin-2, Betacellulin, and PECAM-1 should not be run in serum/plasma samples
  • Recommended Sample Type: Mouse serum, plasma or tissue/cell culture supernatants or lysates
  • Recommended Sample Dilution: 25 μL per well of diluted serum or plasma; cell/tissue culture samples may require diltion in appropriate control medium
  • Assay Run Time: Overnight (16-20 hours) at 2-8°C
  • Research Category: Cancer

Características e benefícios

Design your multiplex kit by choosing available analytes within this panel.

Embalagem

Everything you need in a single kit.

Armazenamento e estabilidade

Recommended storage for kit components is 2 - 8°C.

Outras notas

Please note: Sample Type must be selected when configuring this kit. Angiopoeitin-2, Betacellulin, and PECAM-1 should not be run in serum/plasma samples.
Sensitivity: Refer to kit protocol for sensitivities of individual analytes.

Informações legais

Luminex is a registered trademark of Luminex Corp
MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
xMAP is a registered trademark of Luminex Corp

Exoneração de responsabilidade

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Palavra indicadora

Danger

Classificações de perigo

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2

Órgãos-alvo

Respiratory Tract

Código de classe de armazenamento

10 - Combustible liquids


Certificados de análise (COA)

Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Aziza R Alrafiah
Biomedicines, 9(9) (2021-09-29)
The present study focused on secondary injury following the middle cerebral artery (MCA) occlusion in rats not linked to the MCA's feeding zone. This entity has been very rarely studied. Additionally, this study investigated the rates of expression of five
Wenjie Li et al.
Stem cells international, 2022, 8540535-8540535 (2022-06-18)
Adipose-derived stem cells (ASCs) improve the self-renewal and survival of fat grafts in breast reconstruction after oncology surgery. However, ASCs have also been found to enhance breast cancer growth, and its role in tumor proliferation remains largely elusive. Here, we
Pier-Anne Lachance et al.
PloS one, 8(9), e76078-e76078 (2013-10-03)
During acute inflammation, functioning lymphatics are believed to reduce edema and to provide a transiting route for immune cells, but the extent at which the dermal lymphatic remodeling impacts lymphatic transport or the factors regulating these changes remains unclear. Herein
Sara Luscieti et al.
Blood, 130(17), 1934-1945 (2017-08-05)
Cellular iron homeostasis is controlled by the iron regulatory proteins (IRPs) 1 and 2 that bind cis-regulatory iron-responsive elements (IRE) on target messenger RNAs (mRNA). We identified profilin 2 (Pfn2) mRNA, which encodes an actin-binding protein involved in endocytosis and
Kenny Schlosser et al.
Thorax, 73(3), 248-261 (2017-09-28)
Elevated plasma levels of angiopoietin-2 (ANGPT2) have been reported in patients with acute lung injury (ALI); however, it remains unclear whether this increase contributes to, or just marks, the underlying vasculopathic inflammation and leak associated with ALI. Here we investigated

Conteúdo relacionado

The angiogenesis pathway is complex with many targets to analyze. Simultaneous quantification of multiple markers, with the MILLIPLEX® Human Angiogenesis/Growth Factor Panel 1, saves valuable resources. See how this panel was used to correlate angiogenesis biomarkers with early metastatic progression in NSCLC.

Get even more out of your samples with this Luminex® technology-based mouse cytokine assay – the MILLIPLEX® Mouse Cytokine Expanded Panel 1.

Cancer biomarker detection through MILLIPLEX® multiplex cancer assays can accelerate studies of tumorigenic processes helping advance cancer research.

Questions

1–2 of 2 Questions  
  1. Can the Wash Buffer substitute Sheath Fluid or Drive at the end of a Milliplex assay to resuspend the beads?

    1 answer
    1. The plate can be used in Wash Buffer, but it may not be as stable, and it should be read within a few hours. If you need to store the plate overnight, it should be in Sheath Fluid or Drive Fluid.

      Helpful?

  2. Does the Mouse Angiogenesis panel (MAGPMAG-24K) cross-react with rat samples?

    1 answer
    1. The MAGPMAG-24K kit was tested with 16 rat samples, and the analytes were detected in most of the rat samples. However, no testing was conducted with rat standards to determine cross-reactivity or to validate the kit with rat samples.

      Helpful?

Reviews

No rating value

Active Filters

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica