Pular para o conteúdo
Merck

KHGEG1TTB1H

Millipore

Millipore Express® SHC High Area, Opticap® XLT Capsule

Opticap® XLT 10, non-sterile, pore size 0.5/0.2 μm, cartridge nominal length 10 in. (25 cm)

Sinônimo(s):

Gamma Compatible High Area Opticap® XLT 10 Millipore Express® SHC 0.5  µm/ 0.2  µm 1-1/2 in. TC-1 in. HB

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Código UNSPSC:
23151806

Materiais

polyester support
polyethersulfone
polypropylene
polypropylene housing
polypropylene vent cap
polysulfone
silicone seal

Nível de qualidade

conformidade reg.

meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

esterilidade

non-sterile

Compatibilidade de esterilização

gamma compatible

linha de produto

Opticap® XLT 10

Características

hydrophilic

fabricante/nome comercial

Millipore Express®

Parâmetros

≤56.4 mL/min air diffusion at 2.75 bar (40 psig) and 23 °C (in water)
1.0 bar max. differential pressure (15 psi) at 80 °C (Forward)
2.1 bar max. differential pressure (30 psi) at 25 °C (Reverse; intermittent)
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psi) at 25 °C (Forward)
6.9 bar max. differential pressure (100 psi) at 25 °C (Forward; intermittent)
80 psig max. inlet pressure

técnica(s)

sterile filtration: suitable

Comprimento

37.6 cm (14.8 in.)

Largura

4.2 in.

comprimento nominal do cartucho

10 in. (25 cm)

Diâmetro

10.7 in. (4.2 cm)

área de filtração

1.0 m2

L entrada para a saída

17.5 cm (6.9 in.)

diam. conexão de saída

1 in.

Impurezas

≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)

matriz

Millipore Express® SHC High Area

pore size

0.5/0.2 μm pore size

ponto de bolha

≥4000 mbar (58 psig), air with water at 23 °C

conector

1/4 in. drain/vent hose barb (with double O-ring seal)
inlet sanitary flange
outlet hose barb
(38 mm (1 1/2 in.) Sanitary Flange Inlet and 25 mm (1 in.) Hose Barb Outlet)

aplicação(ões)

sample preparation

Descrição geral

T-line/Gauge Port: T-line

Embalagem

Double Easy-Open bag

Outras notas

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

Nota de preparo

Sterilization Method
Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Nota de análise

Bacterial Retention
Quantitative retention of 107 CFU/cm2Brevundimonas diminuta (ATCC® 19146) per HIMA methodology
TOC/Conductivity
After sterilization and a controlled water flush of 21 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥2 L

Informações legais

ATCC is a registered trademark of American Type Culture Collection
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

Exoneração de responsabilidade

EMD Millipore Corporation certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.

Não está encontrando o produto certo?  

Experimente o nosso Ferramenta de seleção de produtos.


Certificados de análise (COA)

Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica