KHGES015FF3
Cápsula Millipore Express® SHC, Opticap® XL
Opticap® XL 150, sterile, inlet connection diam. 3/4 in., pore size 0.5/0.2 μm, cartridge nominal length 3.8 in. (9.7 cm)
Sinônimo(s):
Opticap Sterile XL 150 Millipore Express SHC 0.5/0.2 μm 3/4 in. TC/TC
About This Item
Produtos recomendados
Materiais
polyethersulfone
polyethylene support
polypropylene (gamma-stable)
polypropylene housing
polypropylene vent cap (Gamma stable)
polysulfone
silicone seal
Nível de qualidade
conformidade reg.
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
esterilidade
irradiated
sterile
linha de produto
Opticap® XL 150
Características
hydrophilic
fabricante/nome comercial
Millipore Express®
Parâmetros
≤1.0 mL/min air diffusion at 2.8 bar (40 psig) and 23 °C (in water)
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
100 psi max. differential pressure (6.9 bar) (intermittent)
2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 23 °C
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 23 °C (intermittent)
80 psi max. differential pressure (5.5 bar) (continuous)
80 psig max. inlet pressure
técnica(s)
sterile filtration: suitable
Comprimento
9.7 cm (3.8 in.)
comprimento nominal do cartucho
3.8 in. (9.7 cm)
Diâmetro
5.6 cm (2.2 in.)
área de filtração
140 cm2
diâm. conexão de entrada
3/4 in.
L entrada para a saída
9.7 cm (3.8 in.)
diam. conexão de saída
3/4 in.
Impurezas
≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
Matriz
Millipore Express® SHC
pore size
0.5/0.2 μm pore size
ponto de bolha
≥4000 mbar (58 psig), air with water at 23 °C
conector
1/4 in. drain/vent hose barb (with double O-ring seal)
inlet sanitary flange
outlet sanitary flange
(19 mm (3/4 in.) Sanitary Flange Inlet and Outlet)
Procurando produtos similares? Visita Guia de comparação de produtos
Descrição geral
Embalagem
Outras notas
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Nota de preparo
3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
Nota de análise
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
After sterilization and a controlled water flush of 1.0 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
Informações legais
Exoneração de responsabilidade
Não está encontrando o produto certo?
Experimente o nosso Ferramenta de seleção de produtos.
O que é o Programa Emprove®?
O programa Emprove® é um sistema que fornece documentação completa e aprofundada sobre os nossos filtros e componentes descartáveis, matérias-primas para a indústria farmacêutica e materiais de partida.
Gratuito - Faça login para baixar
Gratuito - Faça login para baixar
Disponível mediante assinatura ou pagamento de taxa
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Artigos
We discuss the final filtration step of plasmid DNA manufacturing and its key considerations and challenges. Download our free pDNA downstream purification eBook or ask our experts.
Active Filters
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica