HCMP1MAG-19K
MILLIPLEX® Human Complement Panel 1 - Immunology Multiplex Assay
The Human Complement Panel 1 Bead-Based Multiplex Assay kit, using the Luminex xMAP technology, enables the simultaneous analysis of complement proteins and factors in human serum, plasma and cell culture samples.
Sinônimo(s):
Human complement multiplex kit, Luminex® human complement immunoassay, Millipore human complement panel
About This Item
Produtos recomendados
Nível de qualidade
reatividade de espécies
human
fabricante/nome comercial
Milliplex®
assay range
accuracy: 96%
(Mannose-Binding Lectin (MBL))
sensitivity: 0.0051 ng/mL
(Complement C5a)
sensitivity: 0.026 ng/mL
(Adipsin (Complement Factor D))
sensitivity: 0.040 ng/mL
(Mannose-Binding Lectin (MBL))
sensitivity: 0.22 ng/mL
(Complement Factor I)
sensitivity: 0.31 ng/mL
(Complement C2)
sensitivity: 0.36 ng/mL
(Complement C4b)
sensitivity: 1.040 ng/mL
(Complement C5)
standard curve range: 0.069-50 ng/mL
(Adipson/ Complement Factor D)
standard curve range: 0.07-50 ng/mL
(Complement C2)
standard curve range: 0.137-100 ng/mL
(Mannose-Binding Lectin (MBL))
standard curve range: 0.69-500 ng/mL
(Complement Factor I)
standard curve range: 1.37-1,000 ng/mL
(Complement C4b)
standard curve range: 2.74-2,000 ng/mL
(Complement C5)
standard curve range: 4.12-30,000 pg/mL
(Complement C5a)
técnica(s)
multiplexing: suitable
método de detecção
fluorometric (Luminex xMAP)
Condições de expedição
2-8°C
Categorias relacionadas
Descrição geral
MILLIPLEX® Complement Panel 1 Bead Panel is an 7-plex kit to be used for the simultaneous quantification of any or all of the following analytes in serum, plasma or culture supernatant samples: C2, C4B, C5, C5a, Adipsin/Complement Factor D, MBL and Complement Factor I.
The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.
Panel Type: Immune Response
Especificidade
Cross-reactivity between the antibodies and any of the other analytes in this panel is non-detectable or negligible.
Aplicação
- Analytes: C2, C4b, C5, C5a, Adipsin/Factor D, Mannose-Binding Lectin (MBL), and Factor I
- Recommended Sample type: Serum, plasma, and tissue/cell culture supernatant
- Recommended Sample dilution: 1:200 diluted plasma or serum. Tissue culture supernatant may require a dilution with an appropriate control medium prior to assay
- Assay Run Time: Overnight or two-hour primary incubation
- Research Category: Inflammation & Immunology
- Research Subcategory: Inflammation
- Note: To avoid complement activation in samples, which will affect the results, samples should be thawed as rapidly as possible, put on ice and assayed immediately
Características e benefícios
Embalagem
Armazenamento e estabilidade
Informações legais
Exoneração de responsabilidade
Palavra indicadora
Danger
Frases de perigo
Declarações de precaução
Classificações de perigo
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2
Órgãos-alvo
Respiratory Tract
Código de classe de armazenamento
10 - Combustible liquids
Certificados de análise (COA)
Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica