The EF5 dosage required for your samples can vary based on the specific experimental conditions. According to the data sheet provided, for in vivo assays, it is recommended to include a no EF5 injection control and a competed stain antibody control for small animal studies. The EF5 dosage involves making a tail-vein injection using a specific concentration of the drug relative to the animal's weight and freezing tissues in OCT until ready to section.
EF5-30A4M
EF5 Hypoxia Detection Kit, Alexa Fluor™ 488
Sinônimo(s):
Green fluorescent hypoxia detection
About This Item
Produtos recomendados
técnica(s)
immunofluorescence: suitable
immunohistochemistry: suitable
Nível de qualidade
método de detecção
fluorometric
Descrição geral
Advantages of the EF5 Hypoxia Detection Kit:
• EF5 exists in only one form:
Pimidozole, an alternative hypoxia marker, exists in two forms; one of which is charged and very hydrophilic, the other lipophilic. Pimidozole thus has a very complex biodistribution. In contrast, EF5 is lipophilic and uncharged and this allows very rapid and even tissue distribution.
• EF5 binding images can be calibrated to provide quantitative data on the pO2 values of each cell (Koch CJ, 2002):
The fluorescent images obtained from EF5 binding can be calibrated according to camera settings and a “cube-binding” value which is obtained through a separate procedure. The intensity values of calibrated images are directly related to actual tissue pO2 values. As a result, these images provide information regarding not only where hypoxic areas may or may not be, but also data regarding the distribution and levels of hypoxia.
Reference:
Koch CJ (2002) Measurement of absolute oxygen levels in cells and tissues using oxygen sensors and 2-nitroimidazole EF5. Methods in Enzymology 352: 3-31.
Aplicação
Cancer
Componentes
Anti-EF5, clone ELK3-51 Alexa Fluor™ 488 conjugate, 250 ug: (Part No. CS222729). 1 vial containing 125 uL mouse monoclonal antibody, provided at 2 mg/mL and formulated in PBS, 0.1% sodium azide, 30% glycerol and 1.5% BSA. Store at -20°C.
Armazenamento e estabilidade
Informações legais
Exoneração de responsabilidade
Código de classe de armazenamento
10 - Combustible liquids
Certificados de análise (COA)
Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Os clientes também visualizaram
Artigos
Hypoxia detection assays to measure oxygen levels in both live and fixed cells and tissues.
-
Hi, I'm wondering how many normal-sized mice the EF5-30A4 kit would work for?
1 answer-
Helpful?
-
-
What is the recommended waiting period after injecting the animal?
1 answer-
For IV injection in a mouse model, a waiting period of approximately 10 minutes should be adequate. However, for IP injection, it is recommended to wait for at least 30 minutes, as per literature information. This is supported by a study in Neuroscience (1999; 89(4):1357-66) where EF5 solution was administered intraperitoneally 30 minutes prior to each treatment.
Helpful?
-
Active Filters
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica