1.52006
Chromolith® RP-18 endcapped (monolithic) HPLC Columns
L × I.D. 100 mm x 2 mm HPLC Column
Sinônimo(s):
Chromolith® Performance RP-18 endcapped 100-2 HPLC column
About This Item
Produtos recomendados
product name
Chromolith® RP-18 com substituição dos grupos silanol (endcapped), L × I.D. 100 mm x 2 mm HPLC column
Materiais
PEEK column
Nível de qualidade
Agency
suitable for USP L1
linha de produto
Chromolith®
Características
endcapped
embalagem
1 ea of
Extensão da rotulagem
18% Carbon loading
Parâmetros
200 bar pressure
45 °C max. temp.
técnica(s)
HPLC: suitable
LC/MS: suitable
UHPLC-MS: suitable
UHPLC: suitable
mass spectrometry (MS): suitable (High)
coluna C × D.I.
10 cm × 2 mm
matriz
monolithic silica
Grupo ativo da matriz
C18 bonding phase
tamanho de poro
1.5 μm macroporosity
13 nm mesoporosity
operating pH range
2-7.5
técnica de separação
reversed phase
temperatura de armazenamento
no temp limit
Procurando produtos similares? Visita Guia de comparação de produtos
Categorias relacionadas
Descrição geral
Chromolith® Performance RP-18 endcapped 100-2 columns have macropores with 1.5 μm diameter, giving a column efficiency exceeding 100,000 plates/meter. The mesopores are 13 nm (130 Å), the surface modification is octadecylsilane with full end-capping. Chromolith® Performance RP-18 endcapped 100-2 columns fall under the USP L1 Classification. The column efficiency is comparable to a 3-4 μm particle size fully porous particulate column. Chromolith® Performance RP-18 endcapped 100-2 columns are perfectly suitable for LC-MS applications.
The column dimension of 100 mm length and 2 mm I.D. is the best choice for fast separations of complex samples on any U/HPLC System.
The revolutionary, monolithic silica with its unique combination of macropores and mesopores enables:
—Rapid separations at very low column back-pressure
—High matrix tolerance, allowing time and cost savings with simplified workflows
—Cost-savings due to extended column lifetimes
—Connection of columns, flow gradients and the use of mobile phases with higher viscosity
The recommended Guard-columns are:
Chromolith® RP-18 endcapped 5-2 guard cartridges (3 pieces) [1.52009] with the Chromolith® Guard Cartridge Holder (kit) 5 mm x 2 mm [1.52004]
The Chromolith® column coupler can be used to significantly increase the separation efficiency of Chromolith® columns by coupling several columns in series (up to 100,000 plates/per column). [1.51467]
Learn more:
Brochure: Race through your Separations on Any System. Chromolith® Monolithic Silica HPLC Columns
All Supelco HPLC Columns, including monolithic Chromolith® columns, are fully compatible to all HPLC and UHPLC Instruments.
Supelco HPLC Products: The Best Choice for Any LC Instrument
Aplicação
- Rapid Determination of 30 Polyphenols in Tongmai Formula: This study utilized the Chromolith® RP-18 endcapped column in a liquid chromatography-tandem mass spectrometry setup to analyze 30 polyphenolic compounds in a traditional Chinese medicine formula, demonstrating its application in pharmaceutical analysis and quality control of complex herbal formulations (Wang et al., 2017).
- Ultra-fast gradient LC method for omeprazole analysis using a monolithic column: The Chromolith® RP-18 endcapped column was employed in an ultra-fast gradient liquid chromatography method for the analysis of omeprazole in enteric-coated pellets, highlighting its efficiency in pharmaceutical quality control and rapid method development (Borges et al., 2010).
Nota de análise
Pressure: ≤ 55 bar
Performance (anthracene)
Theoretical Plates (N/m) (Anthracene): ≥ 100000
Capacity factor (Anthracene): 3.9 - 4.6
Tailing (USP): 0.90 - 1.30 %
Selectivity
separation factor (anthracene/progesterone): 2.30 - 2.60
Informações legais
produto relacionado
Certificados de análise (COA)
Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Artigos
Monolithic silica HPLC columns enable high-throughput analysis at low back pressure without loss of separation efficiency or peak capacity.
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica