1.05636
HPTLC plates, Silica gel 60 DIOL F₂₅₄s
pkg of 25 plates, plate L × W 20 cm × 10 cm, glass support
Faça loginpara ver os preços organizacionais e de contrato
About This Item
Produtos recomendados
Materiais
glass support
silica gel 60 matrix
Nível de qualidade
Características
binder Organic Polymer
fluorescent indicator
embalagem
pkg of 25 plates
técnica(s)
HPTLC: suitable
espessura da camada
200 μm
placa C × L
20 cm × 10 cm
tamanho de partícula
5-6 μm
tamanho de poro
60 Å medium pore diameter
temperatura de armazenamento
2-30°C
Descrição geral
25 Glass plates 20 x 10 cm
Our NH2, CN and DIOL -modified silica sorbents are less polar then conventional silica phases, making them ideal for separating hydrophilic or charged substances. Our moderately polar cyano- and diol-modified silica plates can be used for both normal phase and reversed phase systems. An alternative to PEI cellulose, amino-modified NH2 plates provide weak basic ion exchange characteristics with special selectivity for charged compounds.
Nota de análise
Specific surface area (according to BET; 5-Pt. measurement): 480 - 540 m²/g
Pore volume (N₂-isotherm): 0.74 - 0.84 ml/g
d 50 (laser diffraction, size distribution): 5 - 7 µm
Layer thickness: 150 - 200 µm
Deviation of layer thickness per plate: ≤ 35 µm
Chromatographic testings:
A) Steroidtest, straight phase
hRf-values
- hydrocortisone, straight phase:
4 - 8
- Reichstein S, straight phase: 11 - 18
- Methyltestosterone, straight phase: 27 - 36
B) Steroid test, reversed phase
- methyltestosterone, steroid test: 48 - 68
- Reichstein S, steroid test: 58 - 78
- hydrocortisone, steroid test: 68 - 88
Typical value determined on an activated plate (120°C, 15 min)
Eluent a) petroleum benzine 40-60°/acetone (80/20 v/v)
Eluent b) acetone/water (30/70 v/v)
Pore volume (N₂-isotherm): 0.74 - 0.84 ml/g
d 50 (laser diffraction, size distribution): 5 - 7 µm
Layer thickness: 150 - 200 µm
Deviation of layer thickness per plate: ≤ 35 µm
Chromatographic testings:
A) Steroidtest, straight phase
hRf-values
- hydrocortisone, straight phase:
4 - 8
- Reichstein S, straight phase: 11 - 18
- Methyltestosterone, straight phase: 27 - 36
B) Steroid test, reversed phase
- methyltestosterone, steroid test: 48 - 68
- Reichstein S, steroid test: 58 - 78
- hydrocortisone, steroid test: 68 - 88
Typical value determined on an activated plate (120°C, 15 min)
Eluent a) petroleum benzine 40-60°/acetone (80/20 v/v)
Eluent b) acetone/water (30/70 v/v)
Certificados de análise (COA)
Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica