Pular para o conteúdo
Merck
Todas as fotos(1)

Documentos

W504904

Sigma-Aldrich

Butyrophenone

≥99%

Sinônimo(s):

1-Benzoylpropane, 1-Phenyl-1-butanone, NSC 8463, Phenyl propyl ketone

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Fórmula linear:
C6H5COCH2CH2CH3
Número CAS:
Peso molecular:
148.20
Beilstein:
508305
Número CE:
Número MDL:
Código UNSPSC:
12164502
ID de substância PubChem:
Número de Flavis:
7.193
NACRES:
NA.21

fonte biológica

synthetic

Ensaio

≥99%

índice de refração

n20/D 1.520 (lit.)

pb

228-230 °C (lit.)

pf

11-13 °C (lit.)

densidade

1.021 g/mL at 25 °C (lit.)

aplicação(ões)

flavors and fragrances

Documentação

see Safety & Documentation for available documents

alérgeno alimentar

no known allergens

Organoléptico

camphoraceous

cadeia de caracteres SMILES

CCCC(=O)c1ccccc1

InChI

1S/C10H12O/c1-2-6-10(11)9-7-4-3-5-8-9/h3-5,7-8H,2,6H2,1H3

chave InChI

FFSAXUULYPJSKH-UHFFFAOYSA-N

Procurando produtos similares? Visita Guia de comparação de produtos

Código de classe de armazenamento

10 - Combustible liquids

Classe de risco de água (WGK)

WGK 3

Ponto de fulgor (°F)

190.4 °F

Ponto de fulgor (°C)

88 °C

Equipamento de proteção individual

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


Certificados de análise (COA)

Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Fabrice Gritti et al.
Journal of chromatography. A, 1410, 118-128 (2015-08-10)
An original method is proposed for the accurate and reproducible measurement of the time-based dispersion properties of short L< 50cm and narrow rc< 50μm tubes at mobile phase flow rates typically used in very high-pressure liquid chromatography (vHPLC). Such tubes
Fabrice Gritti et al.
Journal of chromatography. A, 1420, 54-65 (2015-10-17)
The impact of the column hardware volume (≃ 1.7 μL) on the optimum reduced plate heights of a series of short 2.1 mm × 50 mm columns (hold-up volume ≃ 80-90 μL) packed with 1.8 μm HSS-T3, 1.7 μm BEH-C18
Ruben De Pauw et al.
Journal of chromatography. A, 1420, 129-134 (2015-10-20)
A new system is proposed for applying fast temperature gradients in liquid chromatography. It consists of a 0.7 mm × 150 mm fused-silica column coated with a 50 μm Nickel-layer, which is connecting with a power source and a temperature
Zsolt Székelyhidi et al.
Bioorganic & medicinal chemistry letters, 15(13), 3241-3246 (2005-06-01)
SR protein-specific kinase-1 (SRPK-1) has been identified as a validated target for hepatitis B virus (HBV). A series of novel tricyclic quinoxaline derivatives was designed and synthesised as potential kinase inhibitory antiviral agents and was found to be active and
Nikola Vaňková et al.
Journal of chromatography. A, 1409, 152-158 (2015-07-29)
The effect of gradient steepness on the kinetic performance limits and peak compression effects has been assessed in gradient mode for the separation of phenol derivatives using columns packed with 2.6μm core-shell particles. The effect of mobile-phase velocity on peak

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica