Accéder au contenu
Merck
  • Imprinted nanospheres based on precipitation polymerization for the simultaneous extraction of six urinary benzene metabolites from urine followed by injector port silylation and gas chromatography-tandem mass spectrometric analysis.

Imprinted nanospheres based on precipitation polymerization for the simultaneous extraction of six urinary benzene metabolites from urine followed by injector port silylation and gas chromatography-tandem mass spectrometric analysis.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2015-08-11)
Abhishek Chauhan, Tejasvi Bhatia, Manoj Kumar Gupta, Pathya Pandey, Vivek Pandey, Prem Narain Saxena, Mohana Krishna Reddy Mudiam
RÉSUMÉ

In the present communication, uniformly sized molecularly imprinted polymer (MIP) as nanospheres were synthesized based on precipitation polymerization using dual-template imprinting approach and used it as sorbent for solid phase extraction of six urinary benzene metabolites (UBMs). This approach in combination with injector port silylation (IPS) has been used for the quantitative determination of these UBMs by gas chromatography-tandem mass spectrometry. The MIP was synthesized by using t,t-muconic acid (t,t-MA) and 1,2,4-trihydroxybenzene (THB) as templates, methacrylic acid (MAA) as a monomer, ethyleneglycoldimethacrylate (EGDMA) as crosslinker, acetonitrile and dimethylsulphoxide as a porogen and azobisisobutyronitrile (AIBN) as an initiator. The factors affecting the performance of polymer and IPS were investigated and optimized for the simultaneous determination of UBMs in urine. Binding study of imprinted and non-imprinted polymer (NIP) shows that, MIP possesses higher affinity in comparison to NIP for these analytes. Under the optimum conditions, the method developed was found to be linear with regression coefficients falls in the range of 0.9721-0.9988 for all the analyzed metabolites. The percent recovery of the metabolites analyzed in urine was found to be in the range of 76-89%, while the limit of detection and limit of quantification were found to be in the range of 0.9-9.1ngmL(-1) and 2.8-27ngmL(-1) respectively. The validated method was successfully applied to the real urine samples collected from different groups (kitchen workers, smokers and petroleum workers) and found that the developed method has been promising applications in the routine analysis of urine samples of benzene exposed population.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Sigma-Aldrich
Diméthylsulfoxyde, Hybri-Max, sterile-filtered, BioReagent, suitable for hybridoma, ≥99.7%
Sigma-Aldrich
Diméthylsulfoxyde, for molecular biology
Sigma-Aldrich
Diméthylsulfoxyde, sterile-filtered, BioPerformance Certified, meets EP, USP testing specifications, suitable for hybridoma
Sigma-Aldrich
Diméthylsulfoxyde, ≥99.5% (GC), suitable for plant cell culture
Sigma-Aldrich
Acrylamide, suitable for electrophoresis, ≥99%
Sigma-Aldrich
2,2′-Azobis(2-methylpropionitrile), 98%
Supelco
N,O-Bis(triméthylsilyl)trifluoroacétamide avec triméthylchlorosilane, with 1% trimethylchlorosilane, for GC derivatization, LiChropur
Sigma-Aldrich
Chlorotrimethylsilane, ≥98.0% (GC)
Sigma-Aldrich
Divinylbenzene, technical grade, 80%
Sigma-Aldrich
Ethylene glycol dimethacrylate, 98%, contains 90-110 ppm monomethyl ether hydroquinone as inhibitor
Sigma-Aldrich
Methacrylic acid, contains 250 ppm MEHQ as inhibitor, 99%
Sigma-Aldrich
Chlorotrimethylsilane, purified by redistillation, ≥99%
Sigma-Aldrich
Diméthylsulfoxyde, BioUltra, for molecular biology, ≥99.5% (GC)
Sigma-Aldrich
Acrylamide, for molecular biology, ≥99% (HPLC)
Sigma-Aldrich
N,O-Bis(triméthylsilyl)trifluoroacétamide, ≥99%
Sigma-Aldrich
4-Vinylpyridine, contains 100 ppm hydroquinone as inhibitor, 95%
Sigma-Aldrich
Acrylamide solution, 40%, suitable for electrophoresis, sterile-filtered
Sigma-Aldrich
Acrylamide, suitable for electrophoresis, ≥99% (HPLC), powder
Sigma-Aldrich
Diméthylsulfoxyde, PCR Reagent
Sigma-Aldrich
Hydroquinone, ReagentPlus®, ≥99%
Sigma-Aldrich
Divinylbenzene, technical grade, 55%
Sigma-Aldrich
Trifluoroacetamide, 97%
Sigma-Aldrich
1,2-Dihydroxybenzene, ReagentPlus®, ≥99%
Sigma-Aldrich
Diméthylsulfoxyde, meets EP testing specifications, meets USP testing specifications
Sigma-Aldrich
Pyrocatechol, ≥99%
Sigma-Aldrich
Hydroquinone, ReagentPlus®, 99%
Sigma-Aldrich
Chlorotrimethylsilane, produced by Wacker Chemie AG, Burghausen, Germany, ≥99.0% (GC)
Sigma-Aldrich
8-Octanoyloxypyrene-1,3,6-trisulfonic acid trisodium salt, suitable for fluorescence, ≥90% (HPCE)
Sigma-Aldrich
Chlorotrimethylsilane solution, 1.0 M in THF
Sigma-Aldrich
Hydroquinone, meets USP testing specifications