Accéder au contenu
Merck

In-line coupling of single-drop microextraction with capillary electrophoresis-mass spectrometry.

Analytical and bioanalytical chemistry (2015-09-26)
Jihye Kim, Kihwan Choi, Doo Soo Chung
RÉSUMÉ

Single-drop microextraction (SDME) was in-line coupled with capillary electrophoresis-mass spectrometry to provide sample cleanup and enrichment simultaneously. Since there is no outlet vial in a conventional capillary electrophoresis-electrospray ionization-mass spectrometry (CE-ESI-MS) configuration, it is not easy to hang a single drop in the capillary inlet for extraction. We overcame the difficulty of coupling SDME and CE-MS by using a temporary outlet reservoir. Basic drugs such as methamphetamine, amphetamine, phenethylamine, methoxyphenamine, and mephentermine were extracted from a basic sample solution to an acidic acceptor drop covered with a thin octanol layer formed at the capillary inlet tip. Compared to the CE-MS method in the multiple reaction monitoring (MRM) mode, the in-line SDME-CE-MS/MS technique showed 130∼150-fold enrichment in 10 min. The relative standard deviations (RSDs) of peak height ranged from 9 to 13 %. RSDs can be reduced from 4 to 6 % using mephentermine as an internal standard. We examined the pretreatment of sample with and without SDME from human urine under the full-scan mode, which confirmed that many metabolites were cleaned up by the selective extraction method of SDME. Even if the analytes from human urine were analyzed under the MRM mode used as a mass filter, there was an isobaric compound causing a disturbance to the analysis. However, in-line SDME-CE-MS/MS made it possible to perform a sample cleanup as well as sample enrichment. The research is extremely advantageous in that it is rapid, convenient, and highly sensitive for the analysis of biological samples using a commercially available instrument.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Sigma-Aldrich
2-Propanol, ACS reagent, ≥99.5%
Sigma-Aldrich
Méthanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Acide acétique, glacial, ACS reagent, ≥99.7%
Sigma-Aldrich
Hydroxyde de sodium, ACS reagent, ≥97.0%, pellets
Sigma-Aldrich
Acide acétique, glacial, ReagentPlus®, ≥99%
Sigma-Aldrich
Hydroxyde de sodium, reagent grade, ≥98%, pellets (anhydrous)
Sigma-Aldrich
Acide formique, reagent grade, ≥95%
Sigma-Aldrich
Hydroxyde de sodium solution, 50% in H2O
Sigma-Aldrich
Acide formique, ACS reagent, ≥96%
Sigma-Aldrich
Acétate d′ammonium, ACS reagent, ≥97%
Sigma-Aldrich
Formate d′ammonium, reagent grade, 97%
Sigma-Aldrich
Hydroxyde de sodium solution, BioUltra, for molecular biology, 10 M in H2O
Sigma-Aldrich
Acétate d′ammonium, ≥99.99% trace metals basis
Sigma-Aldrich
2-Propanol, meets USP testing specifications
Sigma-Aldrich
Urée, powder, BioReagent, for molecular biology, suitable for cell culture
Sigma-Aldrich
Acide acétique, glacial, ≥99.99% trace metals basis
Sigma-Aldrich
Hydroxyde de sodium, BioXtra, ≥98% (acidimetric), pellets (anhydrous)
Sigma-Aldrich
Hydroxyde de sodium solution, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
Acide acétique solution, suitable for HPLC
Sigma-Aldrich
Hydroxyde de sodium, puriss., meets analytical specification of Ph. Eur., BP, NF, E524, 98-100.5%, pellets
Sigma-Aldrich
2-Propanol, Laboratory Reagent, ≥99.5%
Sigma-Aldrich
Hydroxyde de sodium, reagent grade, 97%, powder
Sigma-Aldrich
Méthanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Formate d′ammonium, ≥99.995% trace metals basis
Sigma-Aldrich
Acide formique, ACS reagent, ≥88%
Sigma-Aldrich
Hydroxyde de sodium, pellets, semiconductor grade, 99.99% trace metals basis
Supelco
Urea, 8 M (after reconstitution with 16 mL high purity water)
Sigma-Aldrich
Urea solution, BioUltra, ~8 M in H2O
Sigma-Aldrich
Méthanol, BioReagent, ≥99.93%
Sigma-Aldrich
Méthanol, Absolute - Acetone free