Direkt zum Inhalt
Merck
  • Impact of the grinding process on the quantification of ethyl glucuronide in hair using a validated UPLC-ESI-MS-MS method.

Impact of the grinding process on the quantification of ethyl glucuronide in hair using a validated UPLC-ESI-MS-MS method.

Journal of analytical toxicology (2014-10-03)
Natalie Kummer, Sarah M R Wille, Vincent Di Fazio, Maria Del Mar Ramírez Fernández, Michel Yegles, Willy E E Lambert, Nele Samyn
ZUSAMMENFASSUNG

The Society of Hair Testing (SoHT) has provided cutoffs for the quantification of ethyl glucuronide (EtG) in hair to indicate occasional or chronic/excessive alcohol consumption. Although several sensitive methods have been reported, past proficiency test results show a lack of reproducibility. An ultra-performance liquid chromatographic mass spectrometric method (LLOQ of 10 pg EtG/mg hair) has been validated according to the international guidelines, including the successful participation in five proficiency tests. This method was subsequently used to evaluate the impact of different grinding conditions (cut, weakly or extensively pulverized hair samples) on the final measured EtG concentration. Hair from alcohol consumers (n = 2) and commercially available quality control samples (QCs) (n = 2) was used. For the QCs, extensive pulverization led to a significantly higher amount of measured EtG. In the hair samples obtained from volunteers, cut or weakly pulverized hair resulted in EtG concentrations below the LLOQ, while the mean concentrations of 14 and 40 pg EtG/mg hair were determined after extensive pulverization. Differences in sample preparation could partially explain inter-laboratory variability. As the differences in results can lead to a different interpretation even when applying the SoHT cutoffs, it is of interest to standardize sample preparation techniques in the field of EtG hair testing.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Sigma-Aldrich
Acetonitril, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Methanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Acetonitril, HPLC Plus, ≥99.9%
Sigma-Aldrich
Ameisensäure, reagent grade, ≥95%
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Ameisensäure, ACS reagent, ≥96%
Sigma-Aldrich
Acetonitril, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetonitril, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Acetonitril, anhydrous, 99.8%
Sigma-Aldrich
Methanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Ameisensäure, ACS reagent, ≥88%
Sigma-Aldrich
Methanol, BioReagent, ≥99.93%
Sigma-Aldrich
Methanol, Absolute - Acetone free
Sigma-Aldrich
Methanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
USP
Methylalkohol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Acetonitril, biotech. grade, ≥99.93%
Sigma-Aldrich
Ameisensäure, ≥95%, FCC, FG
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Supelco
Ethyl-β-D-glucuronid, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
Supelco
Methanol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Acetonitril, ReagentPlus®, 99%
Sigma-Aldrich
Acetonitril, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Acetonitril, suitable for DNA synthesis, ≥99.9% (GC)
Supelco
Methanol, analytical standard
Supelco
Acetonitril, Pharmaceutical Secondary Standard; Certified Reference Material
USP
Lösungsmittelrückstände Klasse 2 - Acetonitril, United States Pharmacopeia (USP) Reference Standard