ZUSAMMENFASSUNG

Procedures for estimating the measurement uncertainty (MU) of the concentration of a given analyte in a sample are of major concern for analytical chemists. Unfortunately, it is still unclear how and why MU should be assessed. While several possibilities exist, an appropriate approach consists in using method validation data for the evaluation of MU. This was demonstrated by a validation study achieved in the framework of a clinical study related to caffeine in sports medicine, where the results were used for the evaluation of MU. After validation of the method developed using ultra-high pressure liquid chromatography-mass spectrometry for caffeine and its three main metabolites, accuracy profiles were built for each analyte. The first important conclusion is that the developed method was valid for all compounds and met the given specifications for the application (fit for purpose). Relevant estimates of combined standard uncertainty were computed to obtain uncertainty functions, which allow obtaining values of MU as a function of the concentration of the analyte. The great advantage of both uncertainty function and uncertainty profile is the development of a continuous model that enables easy calculation of the standard, expanded and relative expanded uncertainty at any concentration within the validation domain. In fact, the expanded uncertainty interval is assumed to contain 95% of all possible measurements, regardless of the concentration. Finally, the uncertainty function enables the determination of the lowest limit of quantification by selecting adequate acceptance limits, with the limit of quantification being defined as the point where the relative uncertainty equals the acceptance limit threshold. It has to be noted that further discussions remain mandatory to establish which criteria should be applied to define an adequate decision threshold, and the proposal afforded in this work may open new avenues in this direction.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Supelco
Koffein, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Koffein, powder, ReagentPlus®
Sigma-Aldrich
Koffein, anhydrous, 99%, FCC, FG
Sigma-Aldrich
Theophyllin, anhydrous, ≥99%, powder
Sigma-Aldrich
Theobromin, ≥98.0%
USP
Koffein, United States Pharmacopeia (USP) Reference Standard
USP
Koffein-Schmelzpunkt-Standard, United States Pharmacopeia (USP) Reference Standard
Supelco
Coffein Schmelzpunktstandard, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Koffein, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Sigma-Aldrich
Koffein, Sigma Reference Standard, vial of 250 mg
Sigma-Aldrich
1,7-Dimethylxanthin, ~98%, solid
Supelco
Schmelzpunktstandard 235-237°C, analytical standard
Supelco
Theophyllin, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Koffein, anhydrous, tested according to Ph. Eur.
USP
Theophyllin, United States Pharmacopeia (USP) Reference Standard
Supelco
Mettler Toledo Calibration Substance ME 18872, Caffeine, traceable to primary standards (LGC)
Sigma-Aldrich
Koffein, meets USP testing specifications, anhydrous
Supelco
Theobromin, analytical standard
Sigma-Aldrich
Koffein, BioXtra
Theophyllin, European Pharmacopoeia (EP) Reference Standard
Koffein, European Pharmacopoeia (EP) Reference Standard
Koffein für die Systemeignung, European Pharmacopoeia (EP) Reference Standard