Direkt zum Inhalt
Merck

LNEHBA1C401

HbA1c in lyophilisierten Hämolysaten

LNE Certified Reference Material, commutable, JCTLM listed

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

UNSPSC-Code:
41116107
NACRES:
NA.24

Form

liquid

Qualität

commutable, JCTLM listed

Haltbarkeit

limited shelf life, expiry date on the label

Zusammensetzung

lyophilized human blood hemolysates, 100%

IVD

not for in vitro diagnostic use

Lagertemp.

2-8°C

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Allgemeine Beschreibung

LNE CRM HbA1c 401 is a higher-order certified reference material produced by the French metrological institute LNE in compliance with ISO 17034 requirements. This Certified Reference Material LNE CRM HbA1c 401 corresponds to lyophilized human blood hemolysates and is intended for use as quality control materials for the verification of the accuracy of the reference method and routine methods used in clinical laboratories for the quantification of HbA1c in hemolysate or whole blood. Sample commutability was assessed through an extensive study involving seventeen of the most used method for the quantification of HbA1c in clinical laboratory using the difference in bias approach described in the IFCC recommendations on commutability assessment. Commutability results are reported in the certificate of analysis.

Cert_ LNE CRM HbA1c 401

Anwendung

The LNE CRM HbA1c 401 is a reference material designed for use as quality control material. It is intended for evaluating the measurement bias or uncertainty of existing or new measurement procedures for determining HbA1c in hemolysate or whole blood.

Leistungsmerkmale und Vorteile

  • A reliable and consistent reference material for HbA1c measurement in clinical diagnostic assays. 
  • Certified for their HbA1c concentration using the IFCC reference method through LC/MS. 
  • Derived from real patient samples. 
  • This CRM is pooled, tested, and certified by the LNE, which includes extensive commutability studies. 
  • Commutability is assessed for the main routine assays. 
  • Target values are certified using higher-order reference methods that are calibrated using primary standards of certified purity or certified reference materials, which allows the establishment of metrological traceability of results to the SI units. 
  • The accuracy of the reference methods used to certify target values is verified using certified matrix reference materials. 
  • Recognized by the Joint Committee for Traceability in Laboratory Medicine (JCTLM) as higher order standards. 

Sonstige Hinweise

  • Details on storage, safety, usage, and operating instructions are provided in the comprehensive Certificate of Analysis. 
  • This clinical matrix CRM is for research and clinical testing applications. 

Lagerklassenschlüssel

10 - Combustible liquids

WGK

WGK 1

Flammpunkt (°F)

Not applicable

Flammpunkt (°C)

Not applicable


Choose from one of the most recent versions:

Analysenzertifikate (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.