Direkt zum Inhalt
Merck

67261

Supelco

Phthalsäure-bis-2-ethylhexylester

certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

Synonym(e):

Bis-(2-ethylhexyl)-phthalat, DEHP, ‘Dioctyl′-phthalat

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise

Größe auswählen

100 MG
€ 83,90

€ 83,90


Voraussichtliches Versanddatum28. Mai 2025


Bulk-Bestellung anfordern

Größe auswählen

Ansicht ändern
100 MG
€ 83,90

About This Item

Empirische Formel (Hill-System):
C24H38O4
CAS-Nummer:
Molekulargewicht:
390.56
Beilstein:
1890696
EG-Nummer:
MDL-Nummer:
UNSPSC-Code:
41116107
PubChem Substanz-ID:
NACRES:
NA.24

€ 83,90


Voraussichtliches Versanddatum28. Mai 2025


Bulk-Bestellung anfordern

Qualität

certified reference material
TraceCERT®

Qualitätsniveau

Produktlinie

TraceCERT®

Haltbarkeit

limited shelf life, expiry date on the label

Hersteller/Markenname

Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

Methode(n)

HPLC: suitable
gas chromatography (GC): suitable

bp

386 °C (lit.)

Dichte

0.985 g/mL at 20 °C (lit.)

Anwendung(en)

cleaning products
cosmetics
environmental
food and beverages
personal care

Format

neat

SMILES String

CCCCC(CC)COC(=O)c1ccccc1C(=O)OCC(CC)CCCC

InChI

1S/C24H38O4/c1-5-9-13-19(7-3)17-27-23(25)21-15-11-12-16-22(21)24(26)28-18-20(8-4)14-10-6-2/h11-12,15-16,19-20H,5-10,13-14,17-18H2,1-4H3

InChIKey

BJQHLKABXJIVAM-UHFFFAOYSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Allgemeine Beschreibung

This certified reference material (CRM) is produced and certified in accordance with ISO/IEC 17025 and ISO 17034. This CRM is traceable to primary material from an NMI, e.g. NIST or NMIJ.
Certified content by quantitative NMR incl. uncertainty and expiry date are given on the certificate.
Download your certificate at: http://www.sigma-aldrich.com.
This substance is listed on the positive list of the EU regulation 10/2011 for plastics intended to come into contact with food. Find all available reference materials for compounds listed in 10/2011 here

Anwendung

Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.

Verpackung

Bottomless glass bottle. Contents are inside inserted fused cone.

Rechtliche Hinweise

TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany

Piktogramme

Health hazard

Signalwort

Danger

H-Sätze

Gefahreneinstufungen

Repr. 1B

Lagerklassenschlüssel

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

WGK

WGK 1

Flammpunkt (°F)

392.0 °F - Pensky-Martens closed cup

Flammpunkt (°C)

200 °C - Pensky-Martens closed cup


Zulassungslistungen

Zulassungslistungen werden hauptsächlich für chemische Produkte erstellt. Für nicht-chemische Produkte können hier nur begrenzte Angaben gemacht werden. Kein Eintrag bedeutet, dass keine der Komponenten gelistet ist. Es liegt in der Verantwortung des Benutzers, die sichere und legale Verwendung des Produkts zu gewährleisten.

EU REACH SVHC Candidate List

CAS No.

EU REACH Annex XVII (Restriction List)

CAS No.

EU REACH Annex XIV (Authorisation List)

CAS No.

Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Dokumente section.

Wenn Sie Hilfe benötigen, wenden Sie sich bitte an Kundensupport

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

N B Hopf et al.
Toxicology letters, 224(1), 47-53 (2013-10-22)
Phthalates are suspected to be endocrine disruptors. Di(2-ethylhexyl) phthalate (DEHP) is assumed to have low dermal absorption; however, previous in vitro skin permeation studies have shown large permeation differences. Our aims were to determine DEHP permeation parameters and assess extent
Na Rae Song et al.
Environment international, 54, 65-73 (2013-02-19)
Di(2-ethylhexyl) phthalate (DEHP) is one of the common phthalate plasticizers used primarily in soft polyvinyl chloride, which is a plastic polymer that makes up the total weight of goods from 1% up to 40% in many consumer products. The aims
D B Martinez-Arguelles et al.
The Journal of steroid biochemistry and molecular biology, 137, 5-17 (2013-01-22)
Di-(2-ethylhexyl) phthalate (DEHP) is a plasticizer with endocrine disrupting properties that is found ubiquitously in the environment as well as in human amniotic fluid, umbilical cord blood, human milk, semen, and saliva. It is used in the industry to add
Vincent Muczynski et al.
PloS one, 7(10), e48266-e48266 (2012-11-03)
Phthalates have been shown to have reprotoxic effects in rodents and human during fetal life. Previous studies indicate that some members of the nuclear receptor (NR) superfamilly potentially mediate phthalate effects. This study aimed to assess if expression of these
Xi-Feng Zhang et al.
Environmental and molecular mutagenesis, 54(5), 354-361 (2013-04-30)
Diethylhexyl phthalate (DEHP) is an estrogen-like compound widely used as a commercial plasticizer and present in medical devices, tubing, food containers and packaging. It is considered an endocrine disruptor and studies on experimental animals showed that exposure to DEHP can

Artikel

Identification and quantification of the most common extractables originating from single-use equipment by GC/MS and an Extractables and Leachables Screening Standard.

Ascentis® C18 column facilitates LC-UV/MS analysis of extractables from single-use systems, ensuring reliable identification and quantification.

Questions

1–2 of 2 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.